Microbalance Complete Guide
Microbalance measures weight, time and flow rate while you brew, and connects to CoffeeOS so every pour is recorded against the clock. Microbalance Ti works the same way, with a 3,000 g capacity and a larger battery. Everything below applies to both models unless a step says otherwise.

Part 1: The device
Microbalance or Microbalance Ti
The two scales are the same size and have the same buttons, display and timing functions. These are the differences:
| Microbalance | Microbalance Ti | |
|---|---|---|
| Maximum capacity | 2,000 g | 3,000 g |
| Resolution | 0.1 g up to 1,000 g, then 1 g up to 2,000 g | 0.1 g up to 1,000 g, then 1 g up to 3,000 g |
| Battery | 1,000 mAh | 2,500 mAh |
| Charging | 5 V, 0.5 A | 5 V, 1.2 A |
| Color | White | Black |
Microbalance Ti suits large servers, batch brews and longer stretches between charges.
What’s in the box
Microbalance or Microbalance Ti
Heat-insulating silicone mat
Charging cable
Know your Microbalance

Weighing area - the flat top of the scale. Your brewer, server or cup goes here.
LED display - the strip along the front edge. It shows the timer, the flow rate and the weight.
D-Link button - at the left end of the display, marked with a D. It starts and stops the timer.
Power/Tare button - at the right end of the display, marked with a circle. It powers the scale on and off, tares, and switches between grams and ounces.
Charging port - USB-C, on the side of the scale.
Heat-insulating silicone mat - lay it on the weighing area under a hot brewer or server to keep the heat off the scale. Tare with the mat in place.
The display

Timer - in seconds. It only appears while you are timing.
Flow rate - how fast weight is going onto the scale, in grams per second. During a brew, this is how fast you are pouring.
Weight - in grams or ounces, whichever is lit to the right of the number. In grams it reads to 0.1 g up to 1,000 g and to 1 g above that. In ounces it reads to 0.001 oz.
| What you see | What it means |
|---|---|
| Dashes across the whole display | The scale is starting up. Keep the weighing area clear until they finish. |
| Dashes in flow rate and weight | The load is outside the scale’s range. |
| Speaker | Lit when the beep is on. |
| A | Lit when auto-start timing is on. Flashes when auto-start has started the timer. |
| Phone | Lit while the scale is connected to CoffeeOS. |
| Battery | Off when the charge is normal. Flashes quickly when the battery is low, flashes slowly while charging, and stays lit when fully charged. |
| Dimmed display | Standby. Press a button or put something on the scale to wake it. |
The buttons
| Button | Press | What it does |
|---|---|---|
| Power/Tare | Single tap (off) | Powers on |
| Power/Tare | Single tap (on) | Tares |
| Power/Tare | Hold | Powers off |
| Power/Tare | Double tap | Switches between grams and ounces |
| D-Link | Single tap | Starts or stops the timer |
| D-Link | Double tap | Shows system information |
Units: a unit changed on the scale alone doesn’t stay after a restart. Set it in CoffeeOS to keep it.
Weigh
Keep it still. Moving the scale while you use it gives an incorrect weight. If the reading jumps right after power-on, tare it and it settles.
Temperature: use the scale between 5 and 40 °C (41 to 104 °F).
Time a brew
Manual timing. Tap D-Link to start the timer and tap it again to stop. The display flashes the final time and weight. Press either button to go back to weighing.
Auto-start. Turn auto-start on in CoffeeOS and the A icon lights up. When you start pouring, the scale starts the timer, beeps once, and the A icon flashes.
Auto-stop. With auto-stop on, lift your brewer off while the timer is running and the timer pauses, holding the last stable weight. Put it back and timing continues, with the paused time counted. If you stop the timer while it is paused, the display flashes the paused time and the weight from before you lifted the brewer. Press either button to leave timing.
Battery and charging
Charge through the USB-C port with the cable in the box. Microbalance takes a 5 V, 0.5 A supply and Microbalance Ti a 5 V, 1.2 A supply. If the scale beeps only while it is charging, the battery is usually very low. Leave it on charge longer and it normally recovers.
When something looks wrong
| Problem | What to do |
|---|---|
| The reading freezes | The timer has probably been stopped, and the display is holding the final result. Press either button to go back to weighing. |
| The reading jumps at power-on | Tare it. If it keeps drifting while you use it, contact support. |
| The unit changes back after a restart | Set the unit in CoffeeOS. |
| The display freezes on digits or dashes | Update the scale’s firmware in CoffeeOS. |
| A small amount of coffee doesn’t register | Update the scale’s firmware and CoffeeOS. |
| The timer starts before you want it to | Turn auto-start off. |
| It won’t power on, charge, tare or power off | Contact support. |
To contact support, email service@digitizefluid.com with a description of the problem, a video of it happening, and the serial number from the back of the scale.
Specifications
| Microbalance | Microbalance Ti | |
|---|---|---|
| Dimensions | 135 × 135 × 26.5 mm | 135 × 135 × 26.5 mm |
| Maximum capacity | 2,000 g | 3,000 g |
| Minimum weight | 0.2 g | 0.2 g |
| Precision | 0.1 g | 0.1 g |
| Resolution | 0.1 g from 0 to 1,000 g; 1 g from 1,000 to 2,000 g | 0.1 g from 0 to 1,000 g; 1 g from 1,000 to 3,000 g |
| Units | g, oz | g, oz |
| Operating temperature | 5 to 40 °C | 5 to 40 °C |
| Charging port | USB-C | USB-C |
| Charging | 5 V, 0.5 A | 5 V, 1.2 A |
| Battery | 1,000 mAh | 2,500 mAh |
| Warranty | One year from purchase | One year from purchase |
Part 2: Microbalance in CoffeeOS
Use Microbalance with the Brew Recorder in CoffeeOS to record every pour against the clock, with the bloom and each pour marked automatically, and turn a brew you like into a recipe you can follow again. Add a TDS reading from R2 Extract and CoffeeOS calculates extraction from the same brew. CoffeeOS is free, with no purchase necessary.

Connect
When the scale is connected, the phone icon on its display lights up. If you start a brew in the Brew Recorder with no scale connected, this screen comes up first. Tap Connect.

Scale settings
In Device Center, tap your connected scale to open its settings. Set the unit you want the scale to keep, turn the beep on or off, and update the firmware here.
Record a hand brew

The finished record marks the bloom, every pour, and any stir or swirl, level with the moment it happened. From the record you can rename it, convert it to a recipe, add notes and share it.

Choose when recording starts
Tap the three dots at the top right of the Brew Recorder and set Auto-Start.

Off - you start and stop the recording yourself.
On - the Brew Recorder takes over the scale’s own auto-timer, so the timer starts only once the Brew Recorder is ready to record.
Semi-Auto - press D-Link on the scale to arm the timer, and it starts on your first pour. Weighing beans and taring the brewer no longer set it off early.
Record an espresso shot
The Brew Recorder keeps two times: shot time, from start to end, and extraction time, from the first drip to the last. Stop the recording the instant the machine stops and you lose the end of extraction time.

Plot the brew and add TDS
Tap the grid icon on a finished record to plot the brew on the Brew Control Chart. Dose, water and brew time come from the record. Measure TDS with R2 Extract, or type a reading from another refractometer, and CoffeeOS calculates extraction.


Water weight in the Brew Controller
In the Brew Controller, tap Water and choose Device Auto-Fill to import the weight from Microbalance or Microbalance Ti. If the scale is already connected, CoffeeOS selects it automatically.