Microbalance Complete Guide

Microbalance measures weight, time and flow rate while you brew, and connects to CoffeeOS so every pour is recorded against the clock. Microbalance Ti works the same way, with a 3,000 g capacity and a larger battery. Everything below applies to both models unless a step says otherwise.

Microbalance (left) and Microbalance Ti (right).
Microbalance (left) and Microbalance Ti (right).

Part 1: The device

Microbalance or Microbalance Ti

The two scales are the same size and have the same buttons, display and timing functions. These are the differences:

MicrobalanceMicrobalance Ti
Maximum capacity2,000 g3,000 g
Resolution0.1 g up to 1,000 g, then 1 g up to 2,000 g0.1 g up to 1,000 g, then 1 g up to 3,000 g
Battery1,000 mAh2,500 mAh
Charging5 V, 0.5 A5 V, 1.2 A
ColorWhiteBlack

Microbalance Ti suits large servers, batch brews and longer stretches between charges.

What’s in the box

Microbalance or Microbalance Ti
Heat-insulating silicone mat
Charging cable

Know your Microbalance

Microbalance Ti is laid out the same way.
Microbalance Ti is laid out the same way.

Weighing area - the flat top of the scale. Your brewer, server or cup goes here.

LED display - the strip along the front edge. It shows the timer, the flow rate and the weight.

D-Link button - at the left end of the display, marked with a D. It starts and stops the timer.

Power/Tare button - at the right end of the display, marked with a circle. It powers the scale on and off, tares, and switches between grams and ounces.

Charging port - USB-C, on the side of the scale.

Heat-insulating silicone mat - lay it on the weighing area under a hot brewer or server to keep the heat off the scale. Tare with the mat in place.

The display

The display with every segment and icon lit.
The display with every segment and icon lit.

Timer - in seconds. It only appears while you are timing.

Flow rate - how fast weight is going onto the scale, in grams per second. During a brew, this is how fast you are pouring.

Weight - in grams or ounces, whichever is lit to the right of the number. In grams it reads to 0.1 g up to 1,000 g and to 1 g above that. In ounces it reads to 0.001 oz.

What you seeWhat it means
Dashes across the whole displayThe scale is starting up. Keep the weighing area clear until they finish.
Dashes in flow rate and weightThe load is outside the scale’s range.
SpeakerLit when the beep is on.
ALit when auto-start timing is on. Flashes when auto-start has started the timer.
PhoneLit while the scale is connected to CoffeeOS.
BatteryOff when the charge is normal. Flashes quickly when the battery is low, flashes slowly while charging, and stays lit when fully charged.
Dimmed displayStandby. Press a button or put something on the scale to wake it.

The buttons

ButtonPressWhat it does
Power/TareSingle tap (off)Powers on
Power/TareSingle tap (on)Tares
Power/TareHoldPowers off
Power/TareDouble tapSwitches between grams and ounces
D-LinkSingle tapStarts or stops the timer
D-LinkDouble tapShows system information

Units: a unit changed on the scale alone doesn’t stay after a restart. Set it in CoffeeOS to keep it.

Weigh

1.
Place the scale on a hard, flat surface.
2.
Single-tap Power/Tare. Keep the weighing area clear while the dashes run across the display.
3.
Put your brewer, server or cup on the weighing area and single-tap Power/Tare to tare.
4.
Add coffee or water. Flow rate shows how fast the weight is going on.

Keep it still. Moving the scale while you use it gives an incorrect weight. If the reading jumps right after power-on, tare it and it settles.

Temperature: use the scale between 5 and 40 °C (41 to 104 °F).

Time a brew

Manual timing. Tap D-Link to start the timer and tap it again to stop. The display flashes the final time and weight. Press either button to go back to weighing.

Auto-start. Turn auto-start on in CoffeeOS and the A icon lights up. When you start pouring, the scale starts the timer, beeps once, and the A icon flashes.

Auto-stop. With auto-stop on, lift your brewer off while the timer is running and the timer pauses, holding the last stable weight. Put it back and timing continues, with the paused time counted. If you stop the timer while it is paused, the display flashes the paused time and the weight from before you lifted the brewer. Press either button to leave timing.

Battery and charging

Charge through the USB-C port with the cable in the box. Microbalance takes a 5 V, 0.5 A supply and Microbalance Ti a 5 V, 1.2 A supply. If the scale beeps only while it is charging, the battery is usually very low. Leave it on charge longer and it normally recovers.

When something looks wrong

ProblemWhat to do
The reading freezesThe timer has probably been stopped, and the display is holding the final result. Press either button to go back to weighing.
The reading jumps at power-onTare it. If it keeps drifting while you use it, contact support.
The unit changes back after a restartSet the unit in CoffeeOS.
The display freezes on digits or dashesUpdate the scale’s firmware in CoffeeOS.
A small amount of coffee doesn’t registerUpdate the scale’s firmware and CoffeeOS.
The timer starts before you want it toTurn auto-start off.
It won’t power on, charge, tare or power offContact support.

To contact support, email service@digitizefluid.com with a description of the problem, a video of it happening, and the serial number from the back of the scale.

Specifications

MicrobalanceMicrobalance Ti
Dimensions135 × 135 × 26.5 mm135 × 135 × 26.5 mm
Maximum capacity2,000 g3,000 g
Minimum weight0.2 g0.2 g
Precision0.1 g0.1 g
Resolution0.1 g from 0 to 1,000 g; 1 g from 1,000 to 2,000 g0.1 g from 0 to 1,000 g; 1 g from 1,000 to 3,000 g
Unitsg, ozg, oz
Operating temperature5 to 40 °C5 to 40 °C
Charging portUSB-CUSB-C
Charging5 V, 0.5 A5 V, 1.2 A
Battery1,000 mAh2,500 mAh
WarrantyOne year from purchaseOne year from purchase

Part 2: Microbalance in CoffeeOS

Use Microbalance with the Brew Recorder in CoffeeOS to record every pour against the clock, with the bloom and each pour marked automatically, and turn a brew you like into a recipe you can follow again. Add a TDS reading from R2 Extract and CoffeeOS calculates extraction from the same brew. CoffeeOS is free, with no purchase necessary.

Microbalance Ti recording a pour-over in the Brew Recorder.
Microbalance Ti recording a pour-over in the Brew Recorder.

Connect

1.
Download CoffeeOS and open it.
2.
Power on the scale. CoffeeOS shows a connection prompt. Accept it to connect.
3.
If no prompt appears, go to Me, then Device Center, and select your scale.

When the scale is connected, the phone icon on its display lights up. If you start a brew in the Brew Recorder with no scale connected, this screen comes up first. Tap Connect.

With no scale connected, recording waits here.
With no scale connected, recording waits here.

Scale settings

In Device Center, tap your connected scale to open its settings. Set the unit you want the scale to keep, turn the beep on or off, and update the firmware here.

Record a hand brew

1.
Open the Brew Recorder from the Tools tab and select Hand Brew.
2.
Tap Free Brew.
3.
Set the dose. Weigh it on the scale, or tap Dose to type it or import it.
4.
Brew as you normally would. With Auto-Start on or armed, recording begins on your first pour.
5.
Tap Stop when the brew is done.
Recording a hand brew. Weight is the yellow line, flow rate the purple line.
Recording a hand brew. Weight is the yellow line, flow rate the purple line.

The finished record marks the bloom, every pour, and any stir or swirl, level with the moment it happened. From the record you can rename it, convert it to a recipe, add notes and share it.

A finished brew with its bloom and three pours marked.
A finished brew with its bloom and three pours marked.

Choose when recording starts

Tap the three dots at the top right of the Brew Recorder and set Auto-Start.

Brew Recorder settings.
Brew Recorder settings.

Off - you start and stop the recording yourself.

On - the Brew Recorder takes over the scale’s own auto-timer, so the timer starts only once the Brew Recorder is ready to record.

Semi-Auto - press D-Link on the scale to arm the timer, and it starts on your first pour. Weighing beans and taring the brewer no longer set it off early.

Record an espresso shot

1.
Select Espresso at the top of the Brew Recorder home page.
2.
Put your cup on the scale, under the portafilter.
3.
Tap Record Espresso Shot and pull the shot.
4.
Let the recording run until the last drip, then tap Stop.

The Brew Recorder keeps two times: shot time, from start to end, and extraction time, from the first drip to the last. Stop the recording the instant the machine stops and you lose the end of extraction time.

An espresso record with its stages marked.
An espresso record with its stages marked.

Plot the brew and add TDS

Tap the grid icon on a finished record to plot the brew on the Brew Control Chart. Dose, water and brew time come from the record. Measure TDS with R2 Extract, or type a reading from another refractometer, and CoffeeOS calculates extraction.

A brew plotted on the Brew Control Chart from its record.
A brew plotted on the Brew Control Chart from its record.
R2 Extract connected, ready to import TDS.
R2 Extract connected, ready to import TDS.

Water weight in the Brew Controller

In the Brew Controller, tap Water and choose Device Auto-Fill to import the weight from Microbalance or Microbalance Ti. If the scale is already connected, CoffeeOS selects it automatically.