DiFluid CoffMeter M1 User Manual
August 2026, V0.4
Read this manual carefully so you can use this product correctly and safely.
- Thank you for purchasing CoffMeter M1 Moisture Content and Density Meter.
- The information and specifications in this manual may change without notice as the product is improved.
- Every effort was made to make this manual accurate at the time of writing. If you find an error, please let us know.
Video tutorial: watch how to set up and use CoffMeter M1
Using CoffMeter M1 with CoffeeOS: this manual covers operating the device. To sync your moisture and density readings to CoffeeOS and keep them with your coffee, read the CoffMeter M1 Complete Guide.
Every manual, as a web page and a PDF: DiFluid Product Manuals
Caution
- The latest product specifications and details are in the electronic manual. You can download the latest version from DiFluid Product Manuals.
- Do not open the casing unless you are a qualified service technician. Doing so voids the warranty and may damage the device or stop it working.
- DiFluid is not responsible for any damage caused by using this product (including accessories) incorrectly.
- DiFluid is not liable for direct, indirect or special damages arising from defects in this product, even if advised of the possibility of such damages.
- If anything about the device seems wrong, contact the customer service of the store where you bought it.
About the Power Supply
This product uses a lithium-ion battery.
Lithium-Ion Battery Precautions
For safety, follow these precautions when handling the battery:
!If you will not use the device for a long time, charge it fully before storing it, and charge it again from time to time. Storing it with a low battery can damage the hardware.
!Do not take apart or modify the battery. Damaging its safety mechanisms can cause overheating, smoke, explosion or fire.
!Do not charge the battery near flames or in high heat, such as direct sunlight. High temperatures can disable the safety circuits or trigger dangerous chemical reactions.
!If you notice an odor, heat, discoloration, deformation or anything else unusual while using, charging or storing the device, stop using it immediately. Continued use can lead to overheating, smoke, explosion or fire.
Power Usage Precautions
- Charge the device if it will not turn on or the battery is low.
- The charging port is on the bottom of the device. Use the included cable or a standard USB cable.
- A USB power adapter is not included. Use a 5 V / 0.8 A adapter, sold separately.
Package Contents

- Main unit
- Bean Sweeper
- Brush
- USB-C charging cable
- Toolbox
- Manual (including warranty card)
- Product QR code card
Know Your Product

- Main unit. Do not hold this area when moving the device.
- Touch screen.
- Button (power and test).
- Charging port.
To move the device, hold it by the base, as shown in the close-up.
Before Powering On

- Before powering on, make sure nothing else is touching the device.
- Make sure the chamber is empty. The device initializes automatically when it powers on.
- When moving the device, lift it by supporting the bottom with your hand.
Main Screen

| Number | Description |
|---|---|
| 1 | The selected sample type. Tap it to choose green beans, roasted beans, parchment or dried cherries. |
| 2 | The history record number, generated automatically when a measurement is complete. |
| 3 | App connection status. The icon is white when connected to the app and gray when not connected. |
| 4 | Moisture content result. |
| 5 | Density result. |
| 6 | Current temperature of the sample being measured. |
| 7 | Zero. Empty the chamber before you tap Zero, or readings will be inaccurate. (Density zeroes automatically when you power on with an empty chamber, but tap Zero whenever something seems off.) |
| 8 | Test. Tap to start a measurement; all results appear at the same time. |
| 9 | On the main screen, swipe right to open the Menu. (From any screen, swipe right to go back to the previous screen.) |
| 10 | On the main screen, swipe left to view measurement history. |
Settings Page
On the main screen, swipe from left to right to open the Menu (1), then tap Settings (2).


| Number | Description |
|---|---|
| 1 | Bluetooth. On by default. Keep it on to connect to the app and record data. |
| 2 | Temperature Unit. Choose Celsius (°C) or Fahrenheit (°F). |
| 3 | Language. Choose Simplified Chinese, English, Japanese, Traditional Chinese, Korean or Spanish. |
| 4 | Screen Brightness. Adjust it to suit your eyes. |
| 5 | Auto-Power Off. Set the automatic power-off time: Never, 3 minutes, 5 minutes or 10 minutes. |
| 6 | Device Info. Shows the device's unique serial number (SN) and current version number. Scan the QR code to download the app and store your data. |
| 7 | Factory Reset. Press and hold, then swipe right to reset the device. All data and settings are cleared. |
How to Measure
Before you measure
- Select the sample type manually at the top left of the main screen.
- Before testing, remove everything from the chamber, then tap Zero on the main screen so the measurement is accurate.
- If the device reports low weight, shows abnormal results or shows "NA", remove the Bean Sweeper, empty the chamber, tap Zero and test again.
- After spreading the beans, remove the Bean Sweeper before testing.
Calibration material
- Earlier units shipped with one pack of calibration material. A firmware update has since improved the calibration logic, so the device no longer needs the calibration material, and new units ship without it. Earlier units also work normally without it once updated to the latest firmware.
Steps



Connecting to the App
Before you connect
- On your phone, turn on Bluetooth and location services, and grant the app every permission it asks for.
- If the app cannot connect to the device, check that Bluetooth is turned on in the device settings.
Download CoffeeOS
Scan a QR code below to download CoffeeOS.

First Connection
Method 1: power on the device and open the app. The app shows a connection prompt automatically; tap Connect.

Method 2: after powering on, swipe right on the main screen to open the Menu, then tap Settings, then Device Info. Open the scanner in the app and scan the QR code on the device screen to connect.

Reconnecting
Each time you power on the device, open the app and it reconnects automatically.

Updating Device Firmware
Check regularly for new firmware and update the device. New firmware brings a better experience, handy new features and stable performance.
Path: with the app connected to the device, tap Profile → Bluetooth → the device name, then update.

Uploading Data to the App
With the app connected to the device, tap Profile → Data Sync → select the device name, then tap Sync to upload the data.

Specifications
| Item | Specification |
|---|---|
| Name | CoffMeter M1 |
| Model | CM-M101 |
| Measures | Moisture content, density, sample temperature |
| Sample types | Green beans, roasted beans, parchment, dried cherries |
| Moisture content | Accuracy ±0.2% Range 0 to 50% Resolution 0.1% |
| Density | Accuracy ±1 g/L Range 0 to 1200 g/L Resolution 1 g/L |
| Overall dimensions (L × W × H) | 135 × 83 × 83.7 mm |
| Weight (main unit) | 445 g |
| Screen | 2.31-inch HD touch screen |
| Battery | Lithium battery |
| Battery capacity | 2500 mAh |
| Continuous run time | 10 hours |
| Charging time | 4 hours |
| Data storage | 500 records |
| Test time | Moisture and density: 2 seconds or less |
| Operating temperature | 0 to 45 °C |
| Charging port | USB-C |
| Charging input | 5 V DC, 0.8 A |
Cleaning and Maintenance

- If you will not use the device for a long time, charge it fully before storing it. A low battery can damage the hardware.
- After use, brush any residue out of the inner container and the main unit. Residue can affect measurement accuracy.
- Do not use steel wool or other hard materials to clean the inner container or the device body.
Warranty Policy
Faults that occur under normal use are repaired free of charge by DiFluid for one year from the date of purchase.
Not Covered by Warranty
- Products bought outside official authorized sales channels, or without a warranty card and valid invoice.
- Products past the warranty period.
- Faults or damage caused by misuse, modification, disassembly, repair or flashing firmware yourself.
- Faults or damage caused by shipping, moving or dropping the product after purchase.
- Accidental or user damage, such as liquid getting in, the wrong input voltage, overvoltage, or scratches on the screen or casing.
- Faults or damage caused by force majeure, such as fire, earthquake or flood.
Compliance Information
Federal Communications Commission (FCC) Radiation Exposure Statement
The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Caution: any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
CE Compliance Notice
Hereby, Shenzhen Digitizing Fluid Technology Co., Ltd. declares that the radio equipment type CoffMeter M1 (CM-M101) is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.difluidtech.com/support/document
Manufacturer information: Shenzhen Digitizing Fluid Technology Co., Ltd., Room 1602, Jinhua Building, Longhua District, Shenzhen, China.
- Do not use the product at too high or too low a temperature, and never expose it to strong sunlight or a very wet environment. The suitable temperature for the product and accessories is 0 to 45 °C.
- Bluetooth: 2402 MHz to 2480 MHz. EIRP (max): 8.53 dBm.
- CAUTION: risk of explosion if the battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
- If you use a third-party charger, the recommended output of the adapter is 5 V DC / 0.8 A, and the adapter must be a CE-approved type.
- The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.
Shenzhen Digitizing Fluid Technology Co., Ltd.
Room 1602, Jinhua Building, Longhua District, Shenzhen, China
(+86) 0755-23761557