Manual (PDF)

DiFluid Omix Plus User Manual

April 2026

Read this manual carefully so you can use this product correctly and safely.

  • Thank you for purchasing DiFluid Omix Plus.
  • The information and specifications in this manual may change without notice as the product is improved.
  • Every effort was made to make this manual accurate at the time of writing. If you find an error, please let us know.

Video tutorial: watch how to set up and use Omix Plus

Using Omix Plus with CoffeeOS: this manual covers operating the device. To store and share your measurements in CoffeeOS, read the Omix Plus Complete Guide.

Every manual, as a web page and a PDF: DiFluid Product Manuals

Caution

  • Do not open the casing for repairs unless you are a qualified technician. Doing so voids the warranty, may damage the device and may stop it working.
  • DiFluid is not responsible for any damage caused by using this product (including accessories) incorrectly.
  • DiFluid is not liable for direct, indirect or other damages arising from defects in this product, even if advised of the possibility of such damages, and assumes no responsibility for third-party claims.
  • If you notice anything abnormal with the device, contact customer service at the store where you bought it.

Core Functions

Omix Plus measures water activity, moisture content, density, roast color (Agtron), mesh, temperature, humidity, sample temperature, air pressure, altitude and expansion rate in one device. It combines optical and electromagnetic sensing with several fused algorithm models to give fast, precise results.

Product Features

  1. Versatile: measures coffee cherries, green coffee, dried cherries, parchment coffee, roasted coffee and ground coffee, and recognizes the sample type automatically for reliable results.
  2. Water activity: uses the chilled-mirror dew point method to give accurate water activity results in about 30 seconds.
  3. True density: detects the gap rate between beans and applies compensation models to calculate true density.
  4. Single bean volume: reflects the plumpness, density and deformation of the beans, in mm³.
  5. Removable containers: the inner sample container lifts out and changes to suit each test.
  6. Easy calibration: the calibration container covers both moisture content and Agtron, and parameters can be adjusted in the app to keep results accurate.
  7. App data: results are stored in the app, where you can work with them and share them.
  8. OTA updates: new features arrive over Wi-Fi or Bluetooth.
  9. SDK support: connects to third-party platforms.

Know Your Omix Plus

Omix Plus main unit with touchscreen and button, and the sample base with magnetic connector

Sample Containers

Green bean container A, roasted bean container B, ground coffee container C and Agtron calibration container D

!Each container is printed with its letter, A, B, C or D. This manual refers to them by those letters.

ContainerMeasures and useSample types
Container A (green beans)Water activity, moisture content, density, meshFresh cherries, green beans, dried cherries, parchment, roasted beans
Container B (roasted beans)Agtron value of roasted beans; water activity calibrationRoasted beans
Container C (ground coffee)Agtron value of ground coffeeGround coffee
Container D (calibration)Color calibration (Agtron value)None

Specifications

ItemSpecification
NameOmix Plus
ModelCB101 Plus
FunctionsRoast color, water activity, moisture content, density, mesh, temperature and humidity, air pressure and altitude, sample temperature, expansion rate
Sample typesCoffee cherries, green coffee, parchment coffee, dried cherries, roasted coffee, ground coffee
ColorRange 1 to 150 Agtron, accuracy ±0.1 Agtron, resolution 0.1 Agtron
Water activityRange 0.2 to 1 Aw, accuracy ±0.005 Aw, resolution 0.001 Aw
Moisture contentRange 0 to 60%, accuracy ±0.1%, resolution 0.1%
DensityRange 0 to 1500 g/L, accuracy ±0.5 g/L, resolution 0.1 g/L
VolumeRange 0 to 1000 mm³, accuracy ±20 mm³
Mesh9 to 25 mesh
Dimensions (L × W × H)120 × 120 × 170 mm
Weight (main unit and sample base)822 g
Screen3.5-inch HD touchscreen (70.08 × 52.56 mm)
BatteryLithium battery × 2
Data records1000 records
Operating temperature0 to 45 °C
Charging portUSB-C
Charging input5 V ⎓ 2 A

In the Box

  • Omix Plus main unit × 1
  • Sample base × 1
  • Green coffee container (container A) × 1
  • Roasted coffee container (container B) × 1
  • Ground coffee container (container C) × 1
  • Moisture and Agtron calibration container (container D) × 1
  • Water activity calibration solution bottle × 1
  • Coffee spoon × 1
  • Manual (with warranty card) × 1
  • Tray × 1
  • Scraper × 1
  • Brush × 1
  • Tempered glass screen protector × 1
  • USB-C charging cable × 1
  • Toolbox × 1
  • Certificate × 1
  • Test report × 1
  • Quick start guide × 1

About the Power Supply

This product uses lithium-ion batteries. For safety, follow these precautions when handling them:

!If you will not use the device for a long time, charge it fully before storing it, and charge it again from time to time. Storing it with a low battery can damage the hardware.

!Do not take apart or modify the battery. Damaging its safety mechanisms can cause overheating, smoke, explosion or fire.

!Do not charge near flames or in high heat, such as direct sunlight. High temperatures can disable the safety circuits or trigger dangerous chemical reactions.

!If you notice a smell, heat, discoloration, deformation or anything else unusual during use, charging or storage, stop using the product immediately. Continued use can lead to overheating, smoke, explosion or fire.

Power Usage Precautions

  • Charge the device if it will not turn on or the battery is low.
  • Charge through the USB-C port on the side of the main unit, with the included cable or a standard USB cable.
  • A USB power adapter is not included. Use a 5 V / 2 A adapter, sold separately.

Charging

Make sure the batteries are charged before use. Omix Plus has two parts, the main unit and the sample base, and each has its own battery. Charge through the USB-C port.

Charging the main unit on its own charges only its own battery. To charge both batteries at once, attach the main unit to the sample base first.

Main unit lowered onto the sample base, and the charging cable plugged into the side of the main unit
  1. Line up the magnetic connectors so the main unit sits on the sample base.
  2. Plug the charging cable into the charging port on the side of the main unit.

Battery Status

The top right corner of the screen shows the charge of both batteries. The upper number is the main unit battery and the lower number is the sample base battery.

Battery icons: charging, below 15%, and sample base not connected
IconMeaning
GreenThe battery is full.
YellowThe battery is charging.
RedThe battery is below 15%.
XThe sample base is not connected to the main unit.

App Download

Scan a QR code below to download CoffeeOS from Google Play, the App Store or AppGallery.

QR codes for CoffeeOS on Google Play, the App Store and AppGallery

Before You Start

Before turning the device on, always place the empty container A in the sample base. Press the power button to turn it on. The READY screen means the device started correctly.

Empty container A placed in the sample base with the main unit on top, then the READY screen
  1. Place the empty container A in the sample base and cover it with the main unit.
  2. The READY screen appears when startup is complete.

!Do this every time you turn the device on.

Error Messages

If a message appears after startup, follow it:

  • Container Abnormal: place the empty container A in the sample base, then start the device again.
  • Container Not Cleared: empty the container before going on.
Container Abnormal and Container Not Cleared error screens

!If container A is placed correctly and the device still shows an error, contact DiFluid customer support.

!If you turn the device on without the empty container A in place and then tap Initialize Container on the menu screen, your measurement results will be inaccurate.

READY Screen Basics

Swipe Right: Menu

On the READY screen, swipe from left to right to open the menu:

  • Measurement: measure water activity, moisture content and density, and Agtron value.
  • Calibration: calibrate water activity and moisture content and Agtron, or initialize the container.
  • Settings: more Omix Plus settings.
  • History: results from previous tests.

Swipe Left: History

On the READY screen, swipe once from right to left to see the record of the most recent test. Swipe down and tap Historical Data to see all records.

Swipe right from the READY screen for the menu, swipe left for the record history

Settings

On the menu screen, tap Settings:

  • Measurement: adjust the measurement parameters of Omix Plus.
  • General: general device settings such as language and screen brightness.
  • Device Info: more information about your Omix Plus.
  • Factory Reset: press and hold on the screen until the progress bar completes. This clears all history and returns every parameter to its factory setting.
Tap Settings on the menu screen to open the Settings page

Calibration

!Besides regular calibration, large changes in room temperature can affect the accuracy of results. When the temperature changes a lot, calibrate the measurement items before you measure.

Agtron Calibration

1. With the device on, place container D in the sample base and cover it with the main unit.
Container D placed in the sample base and covered with the main unit
2. On the READY screen, swipe from left to right and tap Calibration. On the calibration page, tap Moisture Content & Agtron.
READY screen, then Calibration, then Moisture Content and Agtron

!Calibrate once a week under normal conditions, and any time readings look abnormal.

Water Activity Calibration

1. Prepare the calibration solution (see How to Prepare the Water Activity Calibration Solution).
2. With the device on, place container B in the sample base and pour in all of the solution, including any undissolved salt. Pour carefully and do not tilt the container.
3. Cover with the main unit and let it sit for 2 minutes before calibrating.
Solution poured into container B, main unit placed on top, then wait 2 minutes before calibrating
4. On the READY screen, swipe from left to right and tap Calibration. On the calibration page, tap Water Activity.
READY screen, then Calibration, then Water Activity

!Calibrate once a week under normal conditions, and any time readings look abnormal.

Container Initialization (Moisture and Density)

With the device off, place the empty container A in the sample base. Press and hold the button for 2 seconds to turn the device on. Omix Plus initializes the container automatically during startup, with nothing else for you to do.

Empty container A in the sample base with the main unit on top, then the READY screen

!To initialize manually, place the empty container A in the sample base, swipe from left to right on the READY screen, tap Calibration, then tap Initialize Container.

Testing

Factory default settings:

  • Auto Recognition is on and Auto Water Activity is off. The test steps below assume these defaults.
  • With Auto Recognition on, Omix Plus recognizes the sample type automatically.

With Auto Water Activity on, a water activity measurement starts each time you press the test button. You can also start it yourself later from the combined results page.

Auto Water Activity setting screen

The Sample Type setting lists Auto Detect and each sample type: dry cherry, parchment, green beans, roasted beans and roasted ground coffee. Swipe down to see the full list.

Sample Type setting screen with Auto Detect selected

Water Activity, Moisture Content and Density

1. With the device off, place the empty container A in the sample base, then turn the device on.
2. Take out container A and make sure nothing is left inside. Fill it with the sample and use the scraper to press lightly and level the surface with the top edge. Do not compact the sample.
3. Place the filled container in the sample base.
Container A filled with the sample using the spoon, then placed in the sample base
4. Cover with the main unit, making sure the magnetic connector is fully seated. On the READY screen, press the button or tap anywhere on the screen to start the test.
Main unit placed on the filled sample base, then the READY screen

!Auto Water Activity is off by default, so this test does not show a water activity result. To measure water activity, tap Water Activity on the results page to start it. To show water activity in this mode automatically, swipe from left to right on the READY screen, tap Settings, then turn on Auto Water Activity.

!Allow 2 minutes between water activity tests.

Roast Analysis

1. Use container B for roasted beans or container C for ground coffee. Make sure nothing is left inside, fill it with the sample and use the scraper to level the surface with the top edge. Do not compact the sample.
2. Place the filled container in the sample base.
Container B or C filled with the sample, then placed in the sample base
3. Cover with the main unit, making sure the magnetic connector is fully seated. On the READY screen, press the button or tap anywhere on the screen to start the test.
Main unit placed on the sample base, then press the button to start

!Water activity is not tested with container B or C.

Individual Measurement

You can run each test on its own from the Measurement screen.

Measurement screen with separate Test buttons for Moisture and Density, Water Activity and Roast Level
TestContainerSample types
Moisture content and densityContainer AFresh coffee cherries, green coffee, dried cherries, parchment coffee, roasted coffee
Water activityContainer AFresh coffee cherries, green coffee, dried cherries, parchment coffee, roasted coffee
Roast levelContainer B (beans)Roasted coffee
Container C (ground)Ground coffee
1. Take the container for your test from the table. Make sure nothing is left inside, fill it with the sample and use the scraper to level the surface with the top edge. Place it in the sample base and cover with the main unit.
Container filled with the sample, placed in the sample base and covered with the main unit
2. On the READY screen, swipe from left to right, tap Measurement, then tap Test under the item you want to measure.
READY screen, then Measurement, then the Test button for each item

Results Page

Results page with sample type, moisture and density, water activity, roast level and environment information
ItemMeaning
Sample typeThe type of sample being tested.
Moisture and densityThe sample's moisture content, density and mesh range.
VolumeSingle bean volume, in mm³.
Water activityThe water activity value of the sample.
Roast levelThe Agtron value of the sample.
Environment informationAir temperature, humidity, air pressure and estimated altitude where you are measuring.

Moisture, Density and Mesh Results

Moisture and density results page with mesh, estimated density, gap rate, bulk density, weight and average size
ItemMeaning
MeshThe mesh range of the coffee beans in the sample.
Estimated densityDensity estimated from the gap rate.
Gap rateThe share of gap area in the total area of the sample.
Bulk densityCalculated from the weight of the sample and the volume of the container.
WeightThe weight of the sample.
Average sizeThe average size of the beans (short diameter).

Water Activity Results

Water activity results page with the method, water activity, mirror temperature and bean temperature
ItemMeaning
Water activity (title)The name of the current measurement.
Chilled-mirror dew point methodThe method used to measure water activity.
Water activityThe water activity result of the sample.
Mirror temperatureThe temperature of the mirror during the test.
Beans temperatureThe temperature of the sample during the test.

Roast Degree Results

Roast degree results page with pie chart, average, standard deviation and distribution histogram
ItemMeaning
Sample typeWhether the sample is whole bean or ground coffee.
Roast analysis standardThe standard used for the roast degree on this page.
Roast degreeThe roast degree of the highlighted part of the pie chart.
RatioThe share of the whole sample that falls in the highlighted roast degree.
Average valueThe average roast degree, showing the overall roast of the sample.
Standard deviationHow uniform the roast is. The smaller the value, the more even the roast.
Distribution detailsA histogram of the roast degree distribution across the sample, centered on the average. Swipe down to see it.

How to Prepare the Water Activity Calibration Solution

Make a saturated salt solution as follows:

1. Pour salt into the clean, empty bottle from the toolbox that comes with Omix Plus up to the line marked NaCl. Then add tap, RO or distilled water up to the line marked WATER.
2. Close the cap tightly and shake the bottle well. Wait an hour for the salt to dissolve. Undissolved salt can be poured into container B together with the water when you calibrate.
Solution bottle with the NaCl and WATER fill lines

!When the remaining salt no longer dissolves, the brine is fully saturated.

!Natural or refined table salt is recommended.

!In a cold room, dissolve the salt in warm water, shake well, then let the solution cool to room temperature before calibrating.

Roast Standards

Agtron valueCommonSCA
0 to 30EspressoVery Dark
Above 30 to 40FrenchDark
Above 40 to 50Full CityMedium Dark
Above 50 to 60CityMedium
Above 60 to 70DarkMedium Light
Above 70 to 80MediumLight
Above 80 to 90CinnamonVery Light
Above 90 to 150LightExtremely Light

Warranty

Omix Plus comes with a one-year warranty. Thank you for purchasing our product. If you have any questions, please contact us.

The warranty card in the box records your details (name, address, phone number), the product (name, serial number, date of purchase) and the seller (name and address). Scan the QR code on the card to read the warranty terms.

Compliance Information

Federal Communications Commission (FCC) Radiation Exposure Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

The device has been evaluated to meet general RF exposure requirements and can be used in portable exposure conditions without restriction. Its power is so low that no RF exposure calculation is needed.

CE Compliance Notice

Hereby, Shenzhen Digitizing Fluid Technology Co., Ltd. declares that the radio equipment type DiFluid Omix CB101, CB101 Plus is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.difluid.com/support/document

Manufacturer: Shenzhen Digitizing Fluid Technology Co., Ltd., Room 1602, Jinhua Building, Longhua District, Shenzhen, China.

Do not use the product at very high or very low temperatures, and never expose it to strong sunlight or a very wet environment. The suitable temperature for the product and accessories is 0 to 45 °C.

Operating frequency rangeMax output power
Bluetooth: 2402 to 2480 MHz (EIRP)7.53 dBm
Wi-Fi: 2.412 to 2.472 GHz (EIRP)19.85 dBm

CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.

If you use a third-party charger, the recommended adapter output is 5 V DC / 2 A, and the adapter shall be a CE-approved type.

The SAR limit of Europe is 2.0 W/kg. Device types CB101 and CB101 Plus have been tested against this SAR limit. The highest SAR value reported under this standard during product certification for use worn on the body is 0.315 W/kg. This device was tested for typical body-worn operations with the back of the device kept 0 cm from the body.

Taiwan NCC Notice

Without permission from the NCC, no company, firm or user may change the frequency, increase the power or alter the original characteristics and functions of an approved low-power radio-frequency device. Low-power radio-frequency devices must not affect flight safety or interfere with legal communications. If interference is found, stop using the device immediately and do not use it again until the interference is eliminated. Legal communications means radio communications operated under the Telecommunications Management Act. Low-power radio-frequency devices must accept interference from legal communications or from industrial, scientific and medical radio wave equipment. To keep images from this device from being viewed or taken without permission, change the default password before use and update it regularly.

Shenzhen Digitizing Fluid Technology Co., Ltd.
Room 1602, Jinhua Building, Longhua District, Shenzhen, China
(+86) 0755-23761557
www.difluid.com