Manual (PDF)

DiFluid Microbalance and Microbalance Ti User Manual

July 2024, V2.0

This manual covers both models. They work the same way; where they differ, both values are shown side by side.

  • Thank you for purchasing DiFluid Microbalance or Microbalance Ti, a professional smart digital coffee scale.
  • It is designed for brewing coffee, with weighing, timing, calculating, recording and networking, for pour-over, espresso and other kinds of brewing.
  • You can use it on its own or with the CoffeeOS app (formerly DiFluid Café), where you can learn to brew, create recipes and join the community.

Video tutorial: watch how to set up and use Microbalance and Microbalance Ti

Using Microbalance and Microbalance Ti with CoffeeOS: this manual covers operating the device. To turn on auto-start timing, switch off the beep and record your brews in CoffeeOS, read the Microbalance and Microbalance Ti Complete Guide.

Every manual, as a web page and a PDF: DiFluid Product Manuals

PDF manuals: Microbalance and Microbalance Ti

Product Breakdown

Microbalance parts: Power / Tare button, LED display, D-Link button, weighing area and charging port
ActionPressButton
Power onSingle tapPower / Tare
TareSingle tapPower / Tare
Power offHoldPower / Tare
Change unitsDouble tapPower / Tare
Start or stop the timerSingle tapD-Link
Show device informationDouble tapD-Link

Specifications

Both models share the same size, display and buttons. Capacity, battery and charging differ.

ItemMicrobalanceMicrobalance Ti
ModelDFT-S101DFT-S102
Dimensions (L × W × H)135 × 135 × 26.5 mm135 × 135 × 26.5 mm
Maximum capacity2000 g3000 g
Minimum weight0.2 g0.2 g
Precision0.1 g0.1 g
Resolution0.1 g from 0 to 1000 g
1 g from 1000 to 2000 g
0.1 g from 0 to 1000 g
1 g from 1000 to 3000 g
Unitsg / ozg / oz
Operating temperature5 to 40 °C5 to 40 °C
Charging portUSB-CUSB-C
Charging input5V ⎓ 0.5A5V ⎓ 1.2A
Battery capacity1000 mAh2500 mAh
In the boxMicrobalance ×1
Heat-insulating silicone mat ×1
Charging cable ×1
Microbalance Ti ×1
Heat-insulating silicone mat ×1
Charging cable ×1

Display and Sound

Microbalance LED display: timer, flow rate, status icons and weight
  • Left area: the timer, in seconds. It shows only while the timer is running and is hidden at power-on.
  • Middle area: the flow rate of your pour, in grams per second.
  • Right area: the weight, in grams (g) or ounces (oz). The indicator on the right lights up next to the current unit.
    • Resolution in grams: 0.1 g from 0 to 1000 g, then 1 g from 1000 to 2000 g on Microbalance or 1000 to 3000 g on Microbalance Ti.
    • Resolution in ounces: 0.001 oz.
  • To turn off the beep, use the CoffeeOS app.

Icon Description

StatusWhat the display shows
Starting up"----------" shows while the scale starts. Do not touch it until this clears.
WorkingThe flow rate and weight areas are lit.
StandbyThe whole display dims. A weight change or a button press wakes it.
Out of rangeThe flow rate and weight areas show "-- ----".
Connected to the appApp icon (phone with a check mark) is shown.
Disconnected from the appApp icon is not shown.
Beep onSpeaker icon is shown.
Beep offSpeaker icon is not shown.
Auto-start timing onⒶ icon is shown.
Auto-start timing offⒶ icon is not shown.
Battery normalBattery icon is not shown.
Low batteryBattery icon flashes quickly.
ChargingBattery icon flashes slowly.
Fully chargedBattery icon is shown.

Using the Scale

Manual Timing

  • Tap D-Link to start the timer.
  • Tap D-Link again to stop it. The display freezes and flashes the final result. Press any button to return to normal use.

Auto-Start Timing

  • Turn this on in the CoffeeOS app. The Ⓐ icon lights up.
  • When you start pouring (the flow rate begins to change slowly), the scale starts the timer by itself and beeps once, and the Ⓐ icon flashes.

Auto-Stop Timing

While the timer is running, lifting a weight off the scale pauses the timer and holds the steady weight from just before you lifted it. From the pause, one of two things happens:

  1. You put the weight back: the timer carries on, and the paused time is made up automatically.
  2. You stop the timer by hand: the display flashes, holding the paused time and the steady weight from before the weight was lifted. Timing is finished. Press any button to leave timing mode.

!Do not move the scale while you use it, or the weight reading may be wrong.

Warranty

One-year warranty. Thank you for purchasing our product. If you have any questions about it, please contact us.

The printed manual includes a warranty card with a QR code that links to the full warranty terms. Keep these details for any warranty claim:

  • Your information: name, address, phone number.
  • Product information: product name, serial number, date of purchase.
  • Seller information: seller name and address.

Compliance Information

FCC Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

The device has been evaluated to meet general RF exposure requirements and can be used in portable exposure conditions without restriction.

CE Statement

EU regulatory conformance. RF exposure information: the EIRP power of the device at maximum is below the exempt condition, 20 mW, specified in EN 62479:2010. RF exposure assessment has been performed to prove that this unit will not generate harmful EM emission above the reference level specified in EC Council Recommendation 1999/519/EC.

CE declaration of conformity. Hereby, Shenzhen Digitizing Fluid Technology Co., Ltd. declares that the radio equipment type DFT-S101 is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at www.digitizefluid.com/support/document.

Manufacturer. Shenzhen Digitizing Fluid Technology Co., Ltd., 1602 Jinhua Bldg., Longhua District, Shenzhen, China.

Operating temperature: 0 to 40 °C
Operating frequency (maximum power): Bluetooth 2402 to 2480 MHz (9 dBm)

Certifications

Certification marks: FCC ID 2A26IDFT-S101, CE, KC, Japan radio 204-B00827, CMIIT ID 2022DP19253, EU and UK representatives, recycling marks

FCC ID: 2A26IDFT-S101. CMIIT ID: 2022DP19253. Japan radio certification: 204-B00827.

EU representative: eVatmaster Consulting GmbH, Bettinastr. 30, 60325 Frankfurt am Main, Germany, contact@evatmaster.com
UK representative: EVATOST CONSULTING LTD, Suite 11, First Floor, Moy Road Business Centre, Taffs Well, Cardiff, Wales, CF15 7QR, contact@evatmaster.com

Shenzhen Digitizing Fluid Technology Co., Ltd.
Room 1602, Jinhua Building, Longhua District, Shenzhen, China.
(+86) 0755-23761557
www.difluid.com