DiFluid AirWave User Manual
August 2026, V0.2
Read this manual carefully so you can use AirWave correctly and safely.
- Thank you for purchasing DiFluid AirWave Smart Smoke Eliminator.
- The information and specifications in this manual may change without notice as the product is improved.
- Every effort was made to make this manual accurate at the time of writing. If you find an error, please let us know.
Video tutorial: watch how to set up and use AirWave
Using AirWave with CoffeeOS: this manual covers operating the device. To connect AirWave to CoffeeOS, read the AirWave Complete Guide.
Every manual, as a web page and a PDF: DiFluid Product Manuals
Caution
- The latest product specifications and details are in the digital version of this manual, available at DiFluid Product Manuals.
- DiFluid is not responsible for any damage caused by improper use of this product (including accessories).
- No liability is assumed for any direct, indirect or special damages caused by defects in this product, even if the possibility of such damages has been disclosed.
- If you notice anything abnormal with the device, contact customer service at the store where you bought it.
Safety Precautions
!This appliance can be used by children aged 8 years and above, and by persons with reduced physical, sensory or mental capabilities or lacking experience and knowledge, if they have been given supervision or instruction on using the appliance safely and understand the hazards involved.
!Supervise children to make sure they do not play with the appliance. Children must not clean or maintain it.
!If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or a similarly qualified person to avoid a hazard.
!There is a fire risk if cleaning is not carried out according to the instructions.
!Do not discharge the air into a flue used for exhausting fumes from appliances burning gas or other fuels.
!Follow the regulations that apply to discharging air.
!CAUTION: This appliance is not intended to be used with gas hobs.
!The hot exhaust from AirWave is mostly CO2. Vent it outside through a separate duct. Do not connect the outlet to the roaster's exhaust duct.
!Power outlet:
- For the 220V version of AirWave, use a power outlet rated at 10A or above, and do not share the outlet with other appliances.
- For the 120V version of AirWave, use a power outlet rated at 15A or above, and do not share the outlet with other appliances.
- If the power plug does not fit your socket, use a compatible transformer that matches AirWave's rated voltage and current.
- If the voltage in your roasting space is lower than AirWave's rated voltage, smoke removal performance may suffer.
!Power cord: use only the power cord specified for this product. Do not modify it or replace it with a different type. Doing so can cause electric shock or fire.
!Exhaust vent is hot: do not touch the exhaust or intake vents with bare hands while the device is running. They can cause burns.
!Ventilation: keep the room well ventilated, especially when using a gas roaster.
!Ducting: the included duct withstands up to 150°C. Before use, measure the exhaust temperature at the roaster outlet. If it exceeds 150°C, switch to a high-temperature resistant duct, or nest the roaster's original duct inside the compatible duct.
!Usage environment: do not use the device in places that are very humid, very hot or in direct sunlight.
!Malfunction: use AirWave only for extracting coffee roasting smoke. If AirWave malfunctions, do not take it apart or repair it yourself. Contact official after-sales service at service@digitizefluid.com.
!Cleaning: always disconnect the power before cleaning and maintenance.
!Duct cleaning: check the duct regularly for blockages or damage. Clear a blockage promptly and replace a damaged duct promptly.
!Storage: when AirWave will not be used for a long time, unplug the power cord and store it in a dry, well-ventilated place.
Getting to Know the Components

In the Box

Specifications
| Item | Specification |
|---|---|
| Name | DiFluid AirWave Smart Smoke Eliminator |
| Model | DFT-SF101 This is a universal model. A country code is added to the model number for each region, for example "-EUH" for European Union countries and "-USL" for the United States. |
| Rated voltage | 220V version: 220 to 240V 120V version: 120V |
| Rated frequency | 220V version: 50Hz/60Hz 120V version: 60Hz |
| Rated power | 220V version: 2400W 120V version: 1800W |
| Roasting capacity | 220V version: up to 1 kg 120V version: up to 800 g |
| Maximum airflow | 130 m³/h (80 m³/h with ducts connected) Exceeding this may let smoke leak, depending on the roaster. |
| Max inlet temperature | Below 120°C |
| Heat-resistant duct | Withstands up to 150°C |
| Noise level | <76 dB(A) |
| Total weight (main unit) | About 6.9 kg |
| Dimensions (L × W × H) | 290 × 181 × 318 mm |
| Inlet duct diameter | 100 mm |
| Outlet duct diameter | 100 mm |
| Smoke filter modes | Standard Filtration, Extreme Filtration, Fan Mode |
| Operating modes | Manual Mode, Automatic Mode |
| Machine cleaning | Self-cleaning mode: run once every 50 kg roasted. During long periods without use, run it from time to time to reactivate the catalyst. |
| Power supply | 220V version: 10A 120V version: 15A |
| Contents | AirWave main unit ×1, air duct ×1, screws ×6, heating wire ×1, hose clamps ×3, screwdrivers ×3, silverskin collection module ×1, user manual (including warranty card) ×1, conformity certificate ×1, tutorial QR card ×1 |
Introduction to Core Functions
Thank you for purchasing AirWave, the coffee roast smoke eliminator. AirWave is built to remove the smoke and harmful gases that coffee roasting produces, filtering the smoke so your roasting space stays fresh and healthy. Its advanced catalytic system strips out smoke and odor, and it is easy to operate, safe and reliable: a dependable partner for your roasting.
Product Features
- Powerful suction, fast smoke removal: a high-performance suction system pulls away the smoke produced during roasting quickly and efficiently, keeping the air clean.
- Low-temperature catalytic technology: AirWave NovaCat, a catalyst developed fully in-house, is a new generation of low-temperature, high-efficiency catalytic material made for the coffee industry. Its high thermal conductivity, impact-resistant material heats up fast and starts the catalytic reaction within a short time. Combined with a catalytic additive formula developed in-house, it raises low-temperature catalytic efficiency and resistance to water and toxins, removing as much PM and VOCs as possible. AirWave also collects silverskin and dust.
- Two modes, adjustable filtration: Manual and Automatic modes cover different ways of working, and several filtration levels let you set the purification strength to suit your roast.
- Smart control and OTA updates: AirWave works with DiFluid OmniFlux to adjust airflow automatically, saving energy while staying effective. It also supports on-screen control and remote OTA firmware updates.
- Eco-friendly, safe and reliable: a recyclable, lightweight metal casing and internal catalyst keep the footprint low, and a high-temperature protection system protects both the device and its surroundings.
Instructions for Use
You can connect the ducts with either a loose connection or a tight connection, depending on your setup. If the duct sizes do not match, use an adapter, or sleeve the roaster's own duct together with a matching duct. Use a tight connection at the roaster's exhaust outlet. At AirWave's air inlet, follow the steps below and use a loose connection.
1. Air Inlet Duct Installation
Connect the silverskin collection module to the device's smoke inlet.



Connect the air duct to the silverskin collection module.


Air duct installation
- Route the duct in smooth, gradual curves for the best smoke intake.
2. Air Outlet Duct Installation

3. Powering On and Off
Power plug
- Reset button: the plug has built-in leakage protection. Whenever power returns after a leakage trip, press the reset button by hand to restore power and use the device.
- Test button: pressing it should make the button pop out, which shows the leakage protection is working. After the test, the reset button pops out; press it again to restore power.
- Power on: press the power switch on the back of the device. The screen shows the DiFluid logo, then the home screen.
- Shut down: after roasting, watch the catalyst temperature on the screen. Once it drops below 40°C, press the main power switch to stop the device. Do not cut the power right after roasting; it shortens the life of the heating element.
- Airflow adjustment: in Manual Mode, turn the screen knob to set the airflow to match the amount of smoke your roast produces. A higher airflow pulls smoke in harder, but lowers the catalyst temperature, which weakens purification.
4. Buttons and Screens
Basic operation
- Long press the screen to open the settings page.
- Turn the knob to select options or adjust the fan speed.
- Short press to confirm (select).
- "Ready" on the screen means the device is ready to start. After choosing a mode, short press the screen to start smoke elimination or Fan Mode.
Home screen

- Current filtration level: Standard Filtration, Extreme Filtration or Fan Mode.
- App connection icon: lights up when the app is connected.
- Bluetooth broadcast icon: lights up when Bluetooth is discoverable.
- "Ready" (standby): short press the screen to start smoke purification or Fan Mode.
- Inlet air temperature: the current temperature of the air entering the device.
- Catalyst temperature: the current temperature of AirWave's purification catalyst.
Settings page

- Gear: three levels, Standard Filtration, Extreme Filtration and Fan Mode. Switch between them at any time during the roast as needed.
- Standard Filtration: removes the smoke produced before second crack begins, for roasters of 1 kg capacity or less. Default heating temperature 250°C, maximum recommended fan speed 85%. The decomposed gases may carry a slight odor. (220V high-power version)
- Extreme Filtration: removes the denser smoke produced in the early part of second crack, for roasters of 1 kg capacity or less. Default heating temperature 300°C, maximum recommended fan speed 80%. The decomposed gases may carry a slight odor. (220V high-power version)
- Fan Mode: for the early stage of the roast, when air needs to move but there is no smoke to purify. Heating is off. Default fan speed 95%, adjustable. Running Fan Mode without heating for long periods can shorten the catalyst's life.
The figures above were measured under laboratory conditions. Actual results depend on your setup.
- Modes: Manual Mode or Automatic Mode.
- Manual Mode: after power on, the device starts in Manual Mode at the Extreme Filtration gear with airflow at 65%. Turn the screen knob clockwise or counterclockwise to set the airflow percentage you want.
- Automatic Mode: requires DiFluid OmniFlux. The device adjusts the heating power to the amount of smoke at each stage of the roast and adjusts the airflow on its own.
- Self-Cleaning: select it and the device cleans itself. Decide when to run it based on how well smoke is being removed. Avoid running it often, as it shortens the life of the heating element.
- Bluetooth: turn Bluetooth on or off.
- Temperature unit: choose Celsius (°C) or Fahrenheit (°F).
- Language: set the device language (Simplified Chinese, English, Japanese and others).
- Device information: shows the firmware version, serial number, device name and the QR code for connecting the device to CoffeeOS.
- Factory reset: clears all history and restores the factory default settings.
Cleaning and Maintenance
How often to clean depends on how often you use the device, the roaster connected to it and how much coffee you roast. Follow these recommendations.
1. Daily Surface Cleaning
After each use, wipe the surface of AirWave with a clean, soft cloth. Do not use strong chemical cleaners or abrasive tools; they damage the surface and spoil its appearance.
2. Silverskin Filter and Air Inlet Cleaning
How often the silverskin filter needs cleaning depends on the roaster it is paired with. The filter catches particles larger than 300 microns in diameter. After your first roast, check how much silverskin the filter collected and set your cleaning schedule from that.
Remove the filter screen: loosen the screw (1), then remove the filter (2).

Reinstall the filter screen: refit it only when it is completely dry. It is held in place by a magnet.

- Filter cleaning: remove the filter screen from the silverskin collection module and wash it with water and a neutral detergent. You can use a brush. Reinstall it only when it is completely dry.
- Inlet cleaning: dust builds up in the inlet over time. Loosen it with a brush, then pour it out or vacuum it out.


3. Self-Cleaning Mode
- Run self-cleaning once for every 50 kg of coffee roasted.
- If the device has not been used for a long time, run self-cleaning to reactivate the catalyst so it works properly.
- You can decide when to self-clean based on how well smoke is being removed. Avoid running it often; it shortens the life of the heating element.
App Download
Scan a QR code to download CoffeeOS from Google Play, the App Store or AppGallery.

Common Issues and Solutions
| Problem | Possible cause | Solution |
|---|---|---|
| The display shows a numeric error code | Sensor or temperature fault | Contact customer service at the store or platform where you bought it |
| The device does not turn on | Power not connected or plug loose | Check that the power plug is fully inserted and the power supply works |
| Switch fault | Contact customer service at the store or platform where you bought it | |
| Abnormal airflow or weak suction | Fan fault | Contact customer service at the store or platform where you bought it |
| Fan speed control button fault | Check whether the button is damaged. If it is, contact support | |
| Air duct blocked or damaged | Check for blockages; clear or replace the inlet duct | |
| Poor smoke extraction | Smoke removal material blocked or damaged | Run Self-Cleaning, or contact support to replace the catalyst |
| Silverskin collection module blocked or damaged | Clean or replace the silverskin collection module | |
| Air duct blocked or damaged | Clean or replace the exhaust duct | |
| Abnormal noise during operation | Foreign object inside the device | Contact customer service at the store or platform where you bought it |
| Device not installed securely | Check and refasten the device so it is installed securely |
Error Code Reference Table
This table is for reference only. If an error code appears, contact after-sales service for troubleshooting.
| Component | Component code | Error type | Trigger | Possible cause |
|---|---|---|---|---|
| Mainboard | 0 | 001 | Mainboard temperature too high (>60°C) | Cooling fan faulty or cooling vent blocked |
| Air inlet temperature sensor | 1 | 080 | Temperature too high (>120°C) | 1. Inlet air temperature too high 2. Sensor faulty |
| 040 | Temperature too low (<-50°C) | Sensor fault | ||
| 020, 010, 008 | Sensor circuit fault | Sensor fault | ||
| 004 | Sensor power supply fault | Sensor fault | ||
| Air outlet temperature sensor | 2 | 080 | Temperature too high (>420°C) | 1. Motor stopped, so no air is circulating 2. Sensor faulty |
| 040 | Temperature too low (<-50°C) or sensor circuit fault | Sensor fault | ||
| 020, 010, 008 | Sensor circuit fault | Sensor fault | ||
| 004 | Sensor fault | Sensor fault | ||
| Fan motor | 3 | 001 | Software overcurrent | Motor fault |
| 002 | Hardware overcurrent | Motor fault | ||
| 004 | Overvoltage | Power supply fault | ||
| 008 | Undervoltage | Power supply fault | ||
| 010 | Locked rotor | Motor jammed | ||
| 040 | Phase loss | Motor fault | ||
| 080 | Overheating | Motor overheating | ||
| 200 | Startup error | Motor jammed | ||
| Heating | 4 | 001 | Heating fault | 1. Heating element failure 2. Thyristor (silicon controlled rectifier) damaged |
Warranty Policy
Faults that occur under normal use are repaired free of charge by DiFluid for one year from the date of purchase.
Not Covered by Warranty
- Products bought outside official authorized sales channels, or without a warranty certificate and valid invoice.
- Products past the warranty period.
- Faults or damage caused by misuse, unauthorized modification, disassembly, repair or firmware flashing.
- Faults or damage caused by shipping, handling or dropping the product after purchase.
- Accidental or user-caused damage, such as liquid getting in, the wrong input voltage, overvoltage, or scratches on the screen or casing.
- Faults or damage caused by force majeure, such as fire, earthquake or flood.
Compliance Information
FCC Requirement
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. This device should be installed and operated with a minimum distance of 20 cm between the radiator and your body.
Shenzhen Digitizing Fluid Technology Co., Ltd.
Room 1602, Jinhua Building, Longhua District, Shenzhen, China
(+86) 0755-23761557