Manual (PDF)

DiFluid CoffMeter W1 User Manual

December 2025, V0.3

Read this manual carefully so you can use CoffMeter W1 correctly and safely.

  • Thank you for purchasing CoffMeter W1 Water Activity Meter.
  • The information and specifications in this manual may change without notice as the product is improved.
  • Every effort was made to make this manual accurate at the time of writing. If you find an error, please let us know.

Video tutorial: watch how to set up and use CoffMeter W1

Using CoffMeter W1 with CoffeeOS: this manual covers operating the device. To save your water activity results and keep a record of them in CoffeeOS, read the CoffMeter W1 Complete Guide.

Every manual, as a web page and a PDF: DiFluid Product Manuals

Caution

  • The latest product specifications and details are in the latest version of this manual, which you can always find on DiFluid Product Manuals.
  • Do not open the casing unless you are a qualified service technician. Doing so voids the warranty and may damage the device or stop it working.
  • DiFluid is not responsible for any damage caused by using this product (including accessories) incorrectly.
  • DiFluid is not liable for direct, indirect or special damages arising from defects in this product, even if advised of the possibility of such damages.
  • If anything about the device seems wrong, contact the customer service of the store where you bought it.

About the Power Supply

This product uses a lithium-ion battery. For safety, follow these precautions when handling the battery:

!If you will not use the device for a long time, charge it fully before storing it, and charge it again from time to time. Storing it with a low battery can damage the hardware.

!Do not take apart or modify the battery. Damaging its safety mechanisms can cause overheating, smoke, bursting or fire.

!Do not charge the battery near fire or in high heat, such as direct sunlight. High temperatures can disable the safety circuits or set off dangerous chemical reactions.

!If you notice a strange smell, heat, discoloration, deformation or anything else unusual while using, charging or storing the device, stop using it at once. Continuing can lead to overheating, smoke, bursting or fire.

Power Usage Precautions

  1. Charge the device when it will not turn on or the battery is low.
  2. The charging port is on the bottom of the device. Use the included cable or any standard USB cable.
  3. No USB power adapter is included. Use a standard USB adapter with a 5V/1A output, sold separately.

Package Contents

CoffMeter W1 package contents
  • Main unit
  • Base and sample tray
  • Saturated saline solution bottle ×1
  • USB-C charging cable ×1
  • Spoon ×1
  • Tool kit ×1
  • User manual (with warranty card) ×1
  • Product QR code card ×1

Specifications

ItemSpecification
NameWater Activity Meter
ModelCM-W101
UsePortable desktop testing
SamplesGreen coffee beans, roasted beans
Measurement time2 minutes (device and sample at the same temperature; humidity 40 to 60%)
Accuracy±0.02 aw
Resolution0.001 aw
Measurement range0.05 to 0.99 aw
Operating temperature0 to 45 °C
Operating humidity40 to 60% RH
Dimensions76 mm (diameter) × 52 mm
Screen2.31-inch TFT display
Battery capacity1500 mAh
Operating time8 hours of continuous use (3.5 hours to charge)
History storage500 entries
OtherAir pressure and altitude display

Button and Swipe Operation

StateActionResult
Device offShort or long pressTurns the device on
Device onShort pressOn any screen, opens the measurement screen and starts measuring
Device onLong pressTurns the device off
AnySwipe from left to right on a subpageReturns to the previous page
AnySwipe from right to left on the measurement screenOpens the history records

Main Screen

CoffMeter W1 main screen
  1. Sample number, generated automatically when a measurement finishes.
  2. App connection status: the phone icon is white when connected to the app and gray when not connected.
  3. Battery level. Charge the device right away when the battery is low.
  4. Curve of how the result changes during a single water activity measurement.
  5. Water activity result.
  6. Test button: tap to start a measurement.
  7. Calibrate button: tap to start calibration.
  8. Room temperature, humidity and other readings.

Settings

On the main screen, swipe from left to right to open Settings.

Settings screen
  1. Device Info: shows the device's unique serial number (SN) and current firmware version. Scan the QR code here to download the app and save your data.
  2. Bluetooth Connection: on by default. Keep it on when you connect the app to record data.
  3. Status Bar (Test Page): shows or hides the battery and status icons at the top of the measurement screen.
  4. Temperature Unit: °C or °F.
  5. Language: English, Japanese or Simplified Chinese.
  6. Display Brightness: set it to whatever is comfortable for your eyes.
  7. Auto-Off: Never, 3 minutes, 5 minutes or 10 minutes.
  8. Factory Reset: tap, then press and slide to the right to reset the device and turn it off. All data and settings are cleared.

Calibration

Before you calibrate

  • Calibrate once a day, before you start testing.
  • Prepare the calibration solution 1 hour in advance.
  • The calibration solution can be reused and made ahead of time. Replace it once a month.
  • Do not leave the solution open to the air or in direct sunlight for long, or you will need to make it again.
  • Clean the container soon after testing. Do not leave samples in it for long.

Preparing the Calibration Solution

1. Add salt to the first line on the bottle, then add warm water up to the second line, and shake well.
Salt and water fill lines on the solution bottle
2. Let it stand for 1 hour so the solution is fully saturated. Some salt may stay undissolved in the bottle. That is normal for a saturated solution.

Calibrating

1. Check that there is nothing visible in the container. Clean out any debris.
Checking the container for debris
2. Pour the calibration solution into the container, undissolved salt included, until the bottom is covered. A little more or less does not affect the result.
Pouring the calibration solution into the container
3. Place the container on the base. The base holds it magnetically and lets it float. Turn it slightly clockwise to set it in place.

Correctly seated: when the container sits properly on the base, you can close the main unit to start a measurement or calibration.

Container correctly seated on the base

Floating: when you first put the container down, it floats. Hold the edge and turn it clockwise until it reaches the seated position, then close the main unit.

Turning the container clockwise to seat it
4. Close the main unit and tap "Calibrate" on the main screen. Follow the on-screen instructions, then start the calibration. Calibration takes about 5 minutes.
5. When calibration is complete, press down on the edge of the container and twist it counterclockwise to release it so it floats. You can pour the solution back into its sealed bottle to use again.
Pressing down and turning the container counterclockwise to release it

Testing

!Clean the container soon after testing. Do not leave samples in it for long.

1. Put the sample in the container. Add just enough beans to cover the bottom. A little more or less does not affect the result.
Beans covering the bottom of the container
2. Place the container on the base and close the main unit, as in step 3 of Calibrating.
3. On the main screen, tap "Test". A test takes about 2 minutes when the sample is at room temperature. Tap "Test" again at any point to stop it.
4. When the test is complete, take out the sample and clean the container with a soft brush, ready for the next sample.
Cleaning the container with a soft brush

Connecting to the App

!Turn on Bluetooth on your phone and allow every permission the app asks for, location included.

!If the device will not connect, check in your phone's settings that Bluetooth is on.

Download CoffeeOS

Scan the QR code to download CoffeeOS.

QR codes for downloading CoffeeOS

First Connection

Turn on the device, then open the app. A connection pop-up appears automatically. Tap "Connect".

Connecting CoffMeter W1 to CoffeeOS for the first time

Reconnecting

Once the device is on, just open the app and it reconnects automatically.

CoffMeter W1 reconnecting to CoffeeOS automatically

Updating the Firmware

!Check for new firmware regularly. New firmware improves how the device works, adds useful features and keeps performance stable.

!Update over Wi-Fi or a mobile hotspot for a steadier update.

Where to update: in CoffeeOS, go to the home page and tap Profile → Device Center → your device.

Firmware update path in CoffeeOS

Cleaning and Maintenance

  • If you will not use the device for a long time, charge it fully before storing it. A low battery can damage the hardware.
  • After use, brush any residue off the container and the main unit. Residue can affect measurement accuracy.
  • Do not clean the container or the device body with steel wool or anything else hard.

Warranty Policy

Faults that occur under normal use are repaired free of charge by DiFluid for one year from the date of purchase.

Not Covered by Warranty

  1. Products bought outside DiFluid's official authorized sales channels, or without a warranty certificate and valid invoice.
  2. Products past the warranty period.
  3. Faults or damage caused by misuse, modification, disassembly, repair or flashing firmware yourself.
  4. Faults or damage caused by shipping, moving or dropping the product after purchase.
  5. Accidental or user damage, such as liquid getting in, the wrong input voltage, overvoltage, or scratches on the screen or casing.
  6. Faults or damage caused by force majeure, such as fire, earthquake or flood.

Shenzhen Digitizing Fluid Technology Co., Ltd.
Room 1602, Jinhua Building, Longhua District, Shenzhen, China
(+86) 0755-23761557