The whole job
Pour it hot. Read it.
The whole job
Step one
The well is deep enough to pour into, so there is no pipette, and the magnetic lid closes over the sample for the reading. A shot goes through paper on the way in.
Step two
The same press at 8 °C as at 64 °C. Cooling Curve Compensation measures the sample and the room and calculates where the reading will settle, so the steps never change.
Step three
TDS to ±0.02% repeatability, with the sample temperature beside it, saved on the instrument. You need no phone to take the reading or to look it up later.
Temperature
Read cold brew straight out of the fridge and filter a minute after the kettle, on one instrument, with nothing to change between them.
One reading procedure anywhere from 4 °C to 65 °C, across 0 to 30% TDS, so filter and espresso use one instrument and one procedure.
Extraction, on board
The chart
TDS and extraction are plotted together on the brew control chart. Swipe down to choose percolation, immersion or hybrid, and the target box moves to match the brewer you use.
Stacking
Read the same sample again and the screen shows the average with the spread beside it, so one stray sample never becomes your TDS.
Records
Five hundred readings stay on the instrument, each with its date, temperature and extraction: a production day of sign-offs, or a whole class's brews. Over Bluetooth, CoffeeOS links each one to the bean it was taken on.
A dial-in
1.26%, then 1.29% a minute later. A gap that small comes from a grind step, not the instrument. When a cup tastes sour, the figure shows you whether to look at extraction or at the roast.
Zeroing
Zero once and every reading afterwards is measured from that point. Which water you zero against depends on where the figure is going.
The reference stays fixed, so a figure taken today and one taken in March are the same measurement. Use it when you send the figure to someone else.
The reference is the water you brew with, so the reading shows only what the coffee added. Whatever your water already carries is subtracted when you zero.
Once a week is enough in most places. Zero more often where temperature and humidity swing.
Build
It lives next to a grinder. It gets splashed, knocked, and used with wet hands.
Where it works
Whichever of these is yours, the cooling step comes out of it: the sample is read at the temperature it is, and the figure is on the screen before the next one is poured.
Batch 40 reads the same as batch 1, whether the sample comes warm out of the tank or cold out of the fridge. The figure is on the instrument before anything goes in the can.
Check the batch brew before open and catch the morning it drifts. Extraction is calculated on the screen, so a spec check runs in the time it takes to pour the next one and nobody has to be taught an app.
Hand a class a figure for the coffee they just brewed, inside the session. Six brews per student in ninety minutes, and the chart is on a screen the room can gather around.
Verify a super-automatic is delivering the strength it is programmed for, and put the figure in the service report. Eleven machines before lunch, whatever each one dispensed at, on thirteen hours of battery and an IP67 rating for a van.
A grind step, a different paper, another water. Each attempt is read the same way at the temperature it was brewed at, so the gap between two cups is the thing you changed and not how long each one sat on the counter.
For you
Alongside R2 Extract
R2 Extract is the instrument this one grew out of. These are the rows where the second generation does something the first cannot.
| Specification | R2 Extract | RS Extract |
|---|---|---|
| Sample temperature | 20–40 °C | 4–65 °C |
| Cooling step | Required for anything hot | None |
| Display | Monochrome | 3.5″ color touchscreen |
| Extraction yield | Phone required | On the instrument |
| Stored readings | Phone required | 500 on the instrument |
| Averaging a run | Phone required | On the instrument |
| Evaporation control | Open well | Magnetic sealing lid |
| Languages on the instrument | Numbers only | English, Chinese, Japanese, Korean |
| Battery | 430 mAh · 12 h | 3000 mAh · 13 h continuous, 16 h standby |
| Charge current | 5 V / 0.3 A | 5 V / 0.8 A |
| Ambient operating range | 5–40 °C | 5–45 °C |
Read anything from 4 °C to 65 °C, with extraction on the screen.
Currency and language
Purchases in Saudi Arabia go through our partner Black Knight.
Visit black-knight.com to buy. For other questions, or to claim a preorder, contact service@digitizefluid.com.