Manual (PDF)

DiFluid Omni User Manual

August 2026

Read this manual carefully so you can use this product correctly and safely.

  • Thank you for purchasing DiFluid Omni Professional Roast and Particle Analyzer.
  • The information and specifications in this manual may change without notice as the product is improved.
  • Every effort was made to make this manual accurate at the time of writing. If you find an error, please let us know.

Video tutorial: watch how to set up and use Omni

Using Omni with CoffeeOS: this manual covers operating the device. To see your roast color and particle size results in CoffeeOS and keep them with your coffee, read the Omni Complete Guide.

Every manual, as a web page and a PDF: DiFluid Product Manuals

Know Your Omni

Omni Main Unit

Omni main unit with touchscreen and button
  • Touchscreen
  • Button: power, test and calibration

Particle Analysis Tray

Particle Analysis Tray with USB-C charging port and magnetic connector

The Particle Analysis Tray has the USB-C charging port and the magnetic connector that links it to the main unit.

Roast Analysis Tray

Roast Analysis Tray, deeper side and shallower side

The Roast Analysis Tray has two sides. The deeper side holds coffee beans. Turn it over to use the shallower side for ground coffee.

Tray

Tray

Product Specifications

ItemSpecification
NameProfessional Roast / Particle Analyzer (2-in-1)
ModelDFT-SD101
Dimensions (main unit)109 × 79 × 72 mm (L × W × H)
Weight (main unit)290 g
Screen2.8-inch HD touchscreen
Battery2500 mAh rechargeable lithium battery
Light source (roast analysis)Multi-band NIR light source (850 nm, 940 nm)
Optical sensorTwo-dimensional imaging sensor
Data records500 roast analysis records / 500 particle analysis records
Operating temperature0 to 45 °C
Charging portUSB-C
Charging parameters5V ⎓ 1A

Preparation Before Use

In the Box

  • Omni main unit ×1
  • Particle Analysis Tray ×1
  • Roast Analysis Tray ×1
  • Tray ×1
  • Calibration plate ×1
  • USB-C charging cable ×1
  • Coffee spoon ×1
  • Brush ×1
  • Scraper ×1
  • Coffee ground spoon ×1
  • Velvet bag ×1
  • Protective film ×1
  • Toolbox ×1
  • Test report ×1
  • Manual (including warranty card) ×1

App Download

Scan a QR code below to download CoffeeOS from Google Play, the App Store or AppGallery.

QR codes to download CoffeeOS

Charging

Make sure the battery is fully charged before use. To charge, attach Omni main unit to the Particle Analysis Tray, then connect the included cable to the USB-C port on the side of the Particle Analysis Tray.

Charging Omni through the Particle Analysis Tray
  1. Attach Omni main unit to the Particle Analysis Tray.
  2. Plug the charging cable into the port on the Particle Analysis Tray.

!If you turn the device on while it is charging, the screen first shows "DiFluid" and then the charging status page. Press the button briefly again to go to the "READY" page.

Status Icons

Battery, Bluetooth and WiFi status icons
IconMeaning
Full batteryFully charged
Battery with lightning bolt and percentage (for example 51%)Charging
Phone with check markBluetooth connected
WiFi signalWiFi connected
Phone with check mark and WiFi signalBluetooth and WiFi connected

Basic Operation

Operate with the Button

When the device is off

  • Press the button once to turn the device on. It has finished starting up when the screen shows "READY".

When the device is on

  • Short press: run a test.
  • Short press, then press and hold: roast degree calibration.
  • Quick double press: show device information.
  • Press and hold: the screen shows "Power Off". Release the button to turn the device off.

Operate with the Touchscreen

Touchscreen pages: menu, home page and last results

Swipe right to open the menu page

  1. Roast: run a roast analysis.
  2. Particle: run a particle analysis.
  3. Calibration: calibrate the device.
  4. Settings: more settings for Omni.

Swipe left to open the analysis history

  1. Roast analysis history: swipe left once from the home page to see the last roast analysis result, then swipe down to see all roast analysis history.
  2. Particle analysis history: swipe left twice from the home page to see the last particle analysis result, then swipe down to see all particle analysis history.
  • On the home page, tap the screen to run a test.
  • On any sub-page, swipe right to go back one level.

Function Operation

Three Ways to Start a Test

  1. Press the button: in smart test mode, the device decides by itself whether to run a roast analysis or a particle analysis.
  2. Tap the screen on the home page: in smart test mode, the device decides by itself whether to run a roast analysis or a particle analysis.
  3. Tap "Roast" or "Particle" on the menu page: the device runs that analysis directly.

Roast Analysis

Procedure

1. Use the Roast Analysis Tray together with the Tray. Fill the deeper side with coffee beans, or the shallower side with ground coffee. Level the sample with the scraper so it is flush with the surface of the tray.
2. Press the button to turn the device on, then place the main unit over the Roast Analysis Tray.
3. On the "READY" page, swipe from left to right to open the menu page, then tap "Roast" to start the test. The result appears on the screen when the test is complete.
Roast analysis operation diagram

Roast Analysis Result Page

Roast analysis result page
ItemWhat it shows
Sample TypeWhether the sample being tested is coffee beans or ground coffee.
Roast Analysis StandardThe roast degree standard used for the current result.
Roast DegreeThe roast degree of the highlighted part of the pie chart.
RatioThe share of the sample in the highlighted part of the pie chart.
Average ValueThe average roast degree, which reflects the overall roast degree.
Standard DeviationThe standard deviation of the roast degree, which reflects roast uniformity. The smaller the value, the more even the roast.
Distribution DetailsA detailed histogram of the sample's roast degree, centered on the average value.
Show HistoryAll roast analysis results.

Cautions

  1. Light source: roast analysis uses near-infrared light (850 nm, 940 nm) for testing and analysis. White light is used for supporting functions such as smart test and 0-6 silver skin detection.
  2. Silver skin detection: in Settings you can choose whether silver skin detection is on for coffee beans or ground coffee, and adjust its sensitivity.

Particle Analysis

Procedure

1. Use the coffee ground spoon to put a suitable amount of ground coffee in the center of the Particle Analysis Tray.
2. Press the button to turn the device on, then place the main unit over the Particle Analysis Tray. Make sure the magnetic connectors are joined.
3. On the "READY" page, swipe from left to right to open the menu page, then tap "Particle" to start the test. The result appears on the screen when the test is complete.
Particle analysis operation diagram

Particle Analysis Result Page

Particle analysis result page
ItemWhat it shows
Particle Analysis StandardThe particle analysis standard used for the current result.
Grind SizeThe grind size of the highlighted part of the pie chart.
RatioThe share of the sample in the highlighted part of the pie chart.
CountsThe total number of particles counted in this test.
D50The median particle size, which reflects where the sizes are concentrated.
Standard DeviationThe standard deviation of the particle size, which reflects grind uniformity. The smaller the value, the more uniform the grind.
Distribution DetailsA detailed histogram of the sample's particle size, grouped by the selected particle analysis standard.
Show HistoryAll particle analysis results.

Notes

  1. More than one level spoonful of ground coffee can affect the analysis of the finer particles.
  2. With the Smart Diffusor function on, the device spreads the particles automatically based on their current distribution. If the particles are already evenly spread, it does not spread them again.
  3. The Particle Analysis Tray beeps while it spreads the particles during a test. This is normal.

Sampling Recommendations

  1. For a coarse grind, take two-thirds of a spoonful.
  2. For a fine grind, take no more than one-third of a spoonful.
  3. If you are not sure of the grind, take half a spoonful.
  4. Adjust the amount as needed to get good, even dispersion.

Calibration

Procedure

1. Take the protective cover off the calibration plate.
2. Press the button to turn the device on, then place the main unit over the calibration plate.
3. On the "READY" page, swipe from left to right to open the menu page and tap "Calibration", or press the button briefly and then press and hold it. The screen shows "Success" when calibration is complete.
Calibration operation diagram

iEach Omni has its own calibration plate. If you lose the original plate, you can buy a new one from our online store.

Settings

On the menu page, tap "Settings" to open the settings page.

  1. Roast: settings for roast analysis.
  2. Particle: settings for particle analysis.
  3. General: device settings such as language and screen brightness.
  4. Device Info: more information about your Omni.
  5. Factory Reset: press and hold the reset icon until the progress bar fills (5 seconds) to restore factory settings.

!A factory reset clears all history records, resets all settings and restarts the device.

Standards Specifications

Roast Analysis Standards

AgtronCOMMONSCA
0 to 30Espresso RoastVery Dark
above 30 to 40French RoastDark
above 40 to 50Full City RoastMedium-Dark
above 50 to 60City RoastMedium
above 60 to 70Dark RoastMedium-Light
above 70 to 80Medium RoastLight
above 80 to 90Cinnamon RoastVery Light
above 90 to 150Light RoastExtra Light

Particle Analysis Standards

ISO sieve opening (μm)ASTM sieve numberTyler mesh
3005048
4254035
6003028
8502020
11801614
14001412
17001210
236088

Grind Size Standard

Particle size (μm)Grind size
100 to under 500Fine
500 to under 800Medium Fine
800 to under 1100Medium
1100 to under 1400Medium Coarse
1400 to 2500Coarse

Warranty

Omni comes with a one-year warranty. Scan the QR code on the product warranty card to read the warranty terms.

The warranty card has space for your details (name, address, phone number), the product details (product name, serial number, purchase date) and the seller's details (name and address of the store).

Thank you for purchasing our product. If you have any questions, please contact us.

Shenzhen Digitizing Fluid Technology Co., Ltd.
Room 1602, Jinhua Building, Longhua District, Shenzhen, China
(+86) 0755-23761557