R1 Extract Complete Guide
Part 1: The device
R1 Extract is a pocket coffee refractometer, the first generation of the device that became R2 Extract. It measures the refractive index of a coffee sample and converts it to TDS %, the strength of the cup. Enter that reading in CoffeeOS with your dose and yield to work out extraction.
What’s in the box

R1 Extract
USB-C charging cable
Cleaning cloth
Drawstring bag
Droppers
Know your R1 Extract

Sample dish - the round well at the top, with the prism at its base. Every reading is taken here, so it has to be clean and dry before each sample.
Button - the round control below the logo. It powers R1 Extract on, takes a reading, and starts calibration.
Status bar - the battery level and status icons along the top of the screen.
TDS % - the large number on the screen: the concentration of the sample, as a percentage of total dissolved solids.
Temperature - the temperature of the sample, in °C.
Refractive index - the bottom line of the screen, marked N. It is the raw measurement: how far light bends as it passes through the liquid.
USB-C charging port - on the bottom end.
Back label - the input rating, the TDS range and precision, the serial number, and the QR code used to connect R1 Extract to an app.
How the number is worked out. R1 Extract reads refractive index directly, and the TDS % on the screen is calculated from that refractive index at the sample’s temperature. Refractive index changes with temperature, so the conversion is most accurate once the liquid and the prism have reached the same temperature.
The button
| Press | What it does |
|---|---|
| Short press (off) | Powers on. |
| Short press (on) | Takes a reading. |
| Short press, then press and hold | Starts calibration. Keep holding until the screen shows that calibration is running. |
Keep it clean
Clean and wipe the sample dish before and after every measurement. Coffee left from the last sample, or a film of oil from espresso, changes the next reading.

Rinse the sample dish and the prism at its base with clean water.

Dry the dish completely with the cleaning cloth or a paper towel.
Calibration
Calibration zeroes R1 Extract against a baseline liquid, so it reads 0.0 for water with no coffee in it. Calibrate at the start of a session, and again whenever readings become unstable. You have two choices for the baseline.
Brew water - the same water you brew with. Its own dissolved solids are zeroed out during calibration, so the number you read afterward is what the coffee alone contributed.
Distilled water - a true zero, so the conversion from refractive index to TDS is as accurate as possible. To calculate extraction later, measure your brew water’s TDS separately and subtract it from the coffee result, or the minerals in the water are counted as coffee.

Short press the button.

Use a dropper to put brew water or distilled water on the prism until it is completely covered.

Short press, then press and hold the button until the screen shows that calibration is running.

Calibration is complete when the screen reads 0.0. Wipe the dish dry before your first coffee.
Measuring a sample
Evaporation pushes refractometer readings up. Hot coffee evaporates on the prism, which concentrates what is left and raises the TDS. Measuring the same drop again does the same thing, a little at a time. Let the coffee cool first, and use a fresh drop for every reading.

Short press the button.

Stir the coffee, then use a dropper to cover the prism completely.

Give the sample a few seconds on the prism to reach the same temperature, then short press the button.

The screen shows the TDS %, the sample temperature and the refractive index. Use CoffeeOS to calculate extraction from the TDS.
Sample temperature: measure liquid between 5 and 45 °C. Outside that range the reading will be incorrect.
Espresso: the oils in crema leave a film on the prism. For the most accurate reading, filter the sample through a paper filter first.
Charging
Charge R1 Extract through the USB-C port with the cable in the box. Make sure the device, and the port in particular, is completely dry before you plug it in.
When a reading looks wrong
| What you see | What to do |
|---|---|
| Readings are unstable | Rinse the prism with pure water, wipe it clean, and calibrate again. |
| Reading is higher than expected | The sample may have been hot or left on the prism too long. Clean the dish and measure a fresh, cooled drop. |
| Reading seems incorrect | Check that the liquid covers the prism completely and that the sample is between 5 and 45 °C. |
Specifications
| Specification | Value |
|---|---|
| TDS range | 0–26% |
| TDS precision | ±0.03% |
| Sample temperature | 5–45 °C |
| Charging | USB-C |
| Input | 5 V, 350 mA |
Part 2: R1 Extract in CoffeeOS
R1 Extract measures the strength of your coffee as TDS %. CoffeeOS calculates extraction from that reading with your dose, water and yield, and plots the brew on the Brewing Control Chart. R1 Extract connects to CoffeeOS, which is free to use.
Why measure TDS
TDS is strength: how much dissolved coffee is in the cup. Alongside your dose, water and yield, it gives you extraction: the percentage of the coffee grounds that dissolved into the water.
Strength and extraction together make one point on the Brewing Control Chart. You plot it with the Brew Controller in CoffeeOS. For filter coffee, the Sensory Brew Control Chart shows which kinds of flavor tend to stand out at that strength and extraction, so you can see which way to move your grind, ratio or temperature.

Connect R1 Extract
- Power on R1 Extract and open the Tools tab in CoffeeOS. CoffeeOS scans for nearby devices while the Tools tab is open and shows a pop-up when R1 Extract is detected. Tap it to connect.
- If the pop-up doesn’t appear, open the quick menu at the top right of the Tools tab, choose Scan, and scan the QR code on the back of R1 Extract.
- Once connected, R1 Extract appears in Device Center under My Devices.
Enter a TDS reading
- Open the Brew Controller, choose your brew method, and enter your dose and water.
- Tap the TDS field and choose Device Auto-Fill. With R1 Extract connected, it is selected automatically. Press the button on R1 Extract and the reading is imported into the field.
- You can also type the reading with the number pad, with or without a connection.
- Enter the yield you measured. Without it, CoffeeOS estimates yield from the water, and a measured yield makes the extraction figure considerably more accurate.
- Tap Plot Brew. Swipe between the Sensory, Updated Classic and Classic charts. Espresso uses the classic charts.
Recording the brew: with Microbalance or Microbalance Ti, record the brew in the Brew Recorder, then plot it in the Brew Controller with your R1 Extract reading.
Link readings to your beans
If you track your coffees in the Bean Manager, tap Assign Beans in the Tool Controller at the bottom of the Brew Controller to link the session to a bean. The session then appears under that bean in Bean Insights.