DiFluid Omix Plus User Manual
April 2026
Read this manual carefully so you can use this product correctly and safely.
- Thank you for purchasing DiFluid Omix Plus.
- The information and specifications in this manual may change without notice as the product is improved.
- Every effort was made to make this manual accurate at the time of writing. If you find an error, please let us know.
Video tutorial: watch how to set up and use Omix Plus
Using Omix Plus with CoffeeOS: this manual covers operating the device. To store and share your measurements in CoffeeOS, read the Omix Plus Complete Guide.
Every manual, as a web page and a PDF: DiFluid Product Manuals
Caution
- Do not open the casing for repairs unless you are a qualified technician. Doing so voids the warranty, may damage the device and may stop it working.
- DiFluid is not responsible for any damage caused by using this product (including accessories) incorrectly.
- DiFluid is not liable for direct, indirect or other damages arising from defects in this product, even if advised of the possibility of such damages, and assumes no responsibility for third-party claims.
- If you notice anything abnormal with the device, contact customer service at the store where you bought it.
Core Functions
Omix Plus measures water activity, moisture content, density, roast color (Agtron), mesh, temperature, humidity, sample temperature, air pressure, altitude and expansion rate in one device. It combines optical and electromagnetic sensing with several fused algorithm models to give fast, precise results.
Product Features
- Versatile: measures coffee cherries, green coffee, dried cherries, parchment coffee, roasted coffee and ground coffee, and recognizes the sample type automatically for reliable results.
- Water activity: uses the chilled-mirror dew point method to give accurate water activity results in about 30 seconds.
- True density: detects the gap rate between beans and applies compensation models to calculate true density.
- Single bean volume: reflects the plumpness, density and deformation of the beans, in mm³.
- Removable containers: the inner sample container lifts out and changes to suit each test.
- Easy calibration: the calibration container covers both moisture content and Agtron, and parameters can be adjusted in the app to keep results accurate.
- App data: results are stored in the app, where you can work with them and share them.
- OTA updates: new features arrive over Wi-Fi or Bluetooth.
- SDK support: connects to third-party platforms.
Know Your Omix Plus

Sample Containers

!Each container is printed with its letter, A, B, C or D. This manual refers to them by those letters.
| Container | Measures and use | Sample types |
|---|---|---|
| Container A (green beans) | Water activity, moisture content, density, mesh | Fresh cherries, green beans, dried cherries, parchment, roasted beans |
| Container B (roasted beans) | Agtron value of roasted beans; water activity calibration | Roasted beans |
| Container C (ground coffee) | Agtron value of ground coffee | Ground coffee |
| Container D (calibration) | Color calibration (Agtron value) | None |
Specifications
| Item | Specification |
|---|---|
| Name | Omix Plus |
| Model | CB101 Plus |
| Functions | Roast color, water activity, moisture content, density, mesh, temperature and humidity, air pressure and altitude, sample temperature, expansion rate |
| Sample types | Coffee cherries, green coffee, parchment coffee, dried cherries, roasted coffee, ground coffee |
| Color | Range 1 to 150 Agtron, accuracy ±0.1 Agtron, resolution 0.1 Agtron |
| Water activity | Range 0.2 to 1 Aw, accuracy ±0.005 Aw, resolution 0.001 Aw |
| Moisture content | Range 0 to 60%, accuracy ±0.1%, resolution 0.1% |
| Density | Range 0 to 1500 g/L, accuracy ±0.5 g/L, resolution 0.1 g/L |
| Volume | Range 0 to 1000 mm³, accuracy ±20 mm³ |
| Mesh | 9 to 25 mesh |
| Dimensions (L × W × H) | 120 × 120 × 170 mm |
| Weight (main unit and sample base) | 822 g |
| Screen | 3.5-inch HD touchscreen (70.08 × 52.56 mm) |
| Battery | Lithium battery × 2 |
| Data records | 1000 records |
| Operating temperature | 0 to 45 °C |
| Charging port | USB-C |
| Charging input | 5 V ⎓ 2 A |
In the Box
- Omix Plus main unit × 1
- Sample base × 1
- Green coffee container (container A) × 1
- Roasted coffee container (container B) × 1
- Ground coffee container (container C) × 1
- Moisture and Agtron calibration container (container D) × 1
- Water activity calibration solution bottle × 1
- Coffee spoon × 1
- Manual (with warranty card) × 1
- Tray × 1
- Scraper × 1
- Brush × 1
- Tempered glass screen protector × 1
- USB-C charging cable × 1
- Toolbox × 1
- Certificate × 1
- Test report × 1
- Quick start guide × 1
About the Power Supply
This product uses lithium-ion batteries. For safety, follow these precautions when handling them:
!If you will not use the device for a long time, charge it fully before storing it, and charge it again from time to time. Storing it with a low battery can damage the hardware.
!Do not take apart or modify the battery. Damaging its safety mechanisms can cause overheating, smoke, explosion or fire.
!Do not charge near flames or in high heat, such as direct sunlight. High temperatures can disable the safety circuits or trigger dangerous chemical reactions.
!If you notice a smell, heat, discoloration, deformation or anything else unusual during use, charging or storage, stop using the product immediately. Continued use can lead to overheating, smoke, explosion or fire.
Power Usage Precautions
- Charge the device if it will not turn on or the battery is low.
- Charge through the USB-C port on the side of the main unit, with the included cable or a standard USB cable.
- A USB power adapter is not included. Use a 5 V / 2 A adapter, sold separately.
Charging
Make sure the batteries are charged before use. Omix Plus has two parts, the main unit and the sample base, and each has its own battery. Charge through the USB-C port.
Charging the main unit on its own charges only its own battery. To charge both batteries at once, attach the main unit to the sample base first.

- Line up the magnetic connectors so the main unit sits on the sample base.
- Plug the charging cable into the charging port on the side of the main unit.
Battery Status
The top right corner of the screen shows the charge of both batteries. The upper number is the main unit battery and the lower number is the sample base battery.

| Icon | Meaning |
|---|---|
| Green | The battery is full. |
| Yellow | The battery is charging. |
| Red | The battery is below 15%. |
| X | The sample base is not connected to the main unit. |
App Download
Scan a QR code below to download CoffeeOS from Google Play, the App Store or AppGallery.

Before You Start
Before turning the device on, always place the empty container A in the sample base. Press the power button to turn it on. The READY screen means the device started correctly.

- Place the empty container A in the sample base and cover it with the main unit.
- The READY screen appears when startup is complete.
!Do this every time you turn the device on.
Error Messages
If a message appears after startup, follow it:
- Container Abnormal: place the empty container A in the sample base, then start the device again.
- Container Not Cleared: empty the container before going on.

!If container A is placed correctly and the device still shows an error, contact DiFluid customer support.
!If you turn the device on without the empty container A in place and then tap Initialize Container on the menu screen, your measurement results will be inaccurate.
READY Screen Basics
Swipe Right: Menu
On the READY screen, swipe from left to right to open the menu:
- Measurement: measure water activity, moisture content and density, and Agtron value.
- Calibration: calibrate water activity and moisture content and Agtron, or initialize the container.
- Settings: more Omix Plus settings.
- History: results from previous tests.
Swipe Left: History
On the READY screen, swipe once from right to left to see the record of the most recent test. Swipe down and tap Historical Data to see all records.

Settings
On the menu screen, tap Settings:
- Measurement: adjust the measurement parameters of Omix Plus.
- General: general device settings such as language and screen brightness.
- Device Info: more information about your Omix Plus.
- Factory Reset: press and hold on the screen until the progress bar completes. This clears all history and returns every parameter to its factory setting.

Calibration
!Besides regular calibration, large changes in room temperature can affect the accuracy of results. When the temperature changes a lot, calibrate the measurement items before you measure.
Agtron Calibration


!Calibrate once a week under normal conditions, and any time readings look abnormal.
Water Activity Calibration


!Calibrate once a week under normal conditions, and any time readings look abnormal.
Container Initialization (Moisture and Density)
With the device off, place the empty container A in the sample base. Press and hold the button for 2 seconds to turn the device on. Omix Plus initializes the container automatically during startup, with nothing else for you to do.

!To initialize manually, place the empty container A in the sample base, swipe from left to right on the READY screen, tap Calibration, then tap Initialize Container.
Testing
Factory default settings:
- Auto Recognition is on and Auto Water Activity is off. The test steps below assume these defaults.
- With Auto Recognition on, Omix Plus recognizes the sample type automatically.
With Auto Water Activity on, a water activity measurement starts each time you press the test button. You can also start it yourself later from the combined results page.

The Sample Type setting lists Auto Detect and each sample type: dry cherry, parchment, green beans, roasted beans and roasted ground coffee. Swipe down to see the full list.

Water Activity, Moisture Content and Density


!Auto Water Activity is off by default, so this test does not show a water activity result. To measure water activity, tap Water Activity on the results page to start it. To show water activity in this mode automatically, swipe from left to right on the READY screen, tap Settings, then turn on Auto Water Activity.
!Allow 2 minutes between water activity tests.
Roast Analysis


!Water activity is not tested with container B or C.
Individual Measurement
You can run each test on its own from the Measurement screen.

| Test | Container | Sample types |
|---|---|---|
| Moisture content and density | Container A | Fresh coffee cherries, green coffee, dried cherries, parchment coffee, roasted coffee |
| Water activity | Container A | Fresh coffee cherries, green coffee, dried cherries, parchment coffee, roasted coffee |
| Roast level | Container B (beans) | Roasted coffee |
| Container C (ground) | Ground coffee |


Results Page

| Item | Meaning |
|---|---|
| Sample type | The type of sample being tested. |
| Moisture and density | The sample's moisture content, density and mesh range. |
| Volume | Single bean volume, in mm³. |
| Water activity | The water activity value of the sample. |
| Roast level | The Agtron value of the sample. |
| Environment information | Air temperature, humidity, air pressure and estimated altitude where you are measuring. |
Moisture, Density and Mesh Results

| Item | Meaning |
|---|---|
| Mesh | The mesh range of the coffee beans in the sample. |
| Estimated density | Density estimated from the gap rate. |
| Gap rate | The share of gap area in the total area of the sample. |
| Bulk density | Calculated from the weight of the sample and the volume of the container. |
| Weight | The weight of the sample. |
| Average size | The average size of the beans (short diameter). |
Water Activity Results

| Item | Meaning |
|---|---|
| Water activity (title) | The name of the current measurement. |
| Chilled-mirror dew point method | The method used to measure water activity. |
| Water activity | The water activity result of the sample. |
| Mirror temperature | The temperature of the mirror during the test. |
| Beans temperature | The temperature of the sample during the test. |
Roast Degree Results

| Item | Meaning |
|---|---|
| Sample type | Whether the sample is whole bean or ground coffee. |
| Roast analysis standard | The standard used for the roast degree on this page. |
| Roast degree | The roast degree of the highlighted part of the pie chart. |
| Ratio | The share of the whole sample that falls in the highlighted roast degree. |
| Average value | The average roast degree, showing the overall roast of the sample. |
| Standard deviation | How uniform the roast is. The smaller the value, the more even the roast. |
| Distribution details | A histogram of the roast degree distribution across the sample, centered on the average. Swipe down to see it. |
How to Prepare the Water Activity Calibration Solution
Make a saturated salt solution as follows:

!When the remaining salt no longer dissolves, the brine is fully saturated.
!Natural or refined table salt is recommended.
!In a cold room, dissolve the salt in warm water, shake well, then let the solution cool to room temperature before calibrating.
Roast Standards
| Agtron value | Common | SCA |
|---|---|---|
| 0 to 30 | Espresso | Very Dark |
| Above 30 to 40 | French | Dark |
| Above 40 to 50 | Full City | Medium Dark |
| Above 50 to 60 | City | Medium |
| Above 60 to 70 | Dark | Medium Light |
| Above 70 to 80 | Medium | Light |
| Above 80 to 90 | Cinnamon | Very Light |
| Above 90 to 150 | Light | Extremely Light |
Warranty
Omix Plus comes with a one-year warranty. Thank you for purchasing our product. If you have any questions, please contact us.
The warranty card in the box records your details (name, address, phone number), the product (name, serial number, date of purchase) and the seller (name and address). Scan the QR code on the card to read the warranty terms.
Compliance Information
Federal Communications Commission (FCC) Radiation Exposure Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.
The device has been evaluated to meet general RF exposure requirements and can be used in portable exposure conditions without restriction. Its power is so low that no RF exposure calculation is needed.
CE Compliance Notice
Hereby, Shenzhen Digitizing Fluid Technology Co., Ltd. declares that the radio equipment type DiFluid Omix CB101, CB101 Plus is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.difluid.com/support/document
Manufacturer: Shenzhen Digitizing Fluid Technology Co., Ltd., Room 1602, Jinhua Building, Longhua District, Shenzhen, China.
Do not use the product at very high or very low temperatures, and never expose it to strong sunlight or a very wet environment. The suitable temperature for the product and accessories is 0 to 45 °C.
| Operating frequency range | Max output power |
|---|---|
| Bluetooth: 2402 to 2480 MHz (EIRP) | 7.53 dBm |
| Wi-Fi: 2.412 to 2.472 GHz (EIRP) | 19.85 dBm |
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
If you use a third-party charger, the recommended adapter output is 5 V DC / 2 A, and the adapter shall be a CE-approved type.
The SAR limit of Europe is 2.0 W/kg. Device types CB101 and CB101 Plus have been tested against this SAR limit. The highest SAR value reported under this standard during product certification for use worn on the body is 0.315 W/kg. This device was tested for typical body-worn operations with the back of the device kept 0 cm from the body.
Taiwan NCC Notice
Without permission from the NCC, no company, firm or user may change the frequency, increase the power or alter the original characteristics and functions of an approved low-power radio-frequency device. Low-power radio-frequency devices must not affect flight safety or interfere with legal communications. If interference is found, stop using the device immediately and do not use it again until the interference is eliminated. Legal communications means radio communications operated under the Telecommunications Management Act. Low-power radio-frequency devices must accept interference from legal communications or from industrial, scientific and medical radio wave equipment. To keep images from this device from being viewed or taken without permission, change the default password before use and update it regularly.
Shenzhen Digitizing Fluid Technology Co., Ltd.
Room 1602, Jinhua Building, Longhua District, Shenzhen, China
(+86) 0755-23761557
www.difluid.com