AirWave Complete Guide
Part 1: The device
AirWave draws the exhaust from your roaster through a heated catalyst, which breaks the smoke and odor compounds down into carbon dioxide and water vapor. It handles batches up to 1 kg on the 220 V version and up to 800 g on the 120 V version, so you can roast in a home, a shopfront or a sample lab without a hood or an exhaust stack.

What’s in the box

AirWave Main Unit
Air Duct
Silverskin Collection Module
Hose Clamp × 3
Heating Wire (replacement part)
Screws × 6
Screwdriver × 3
User Manual (with warranty card), Certificate of Conformity and Tutorial QR Card
The duct for the air outlet is not in the box. You need a high-temperature-resistant duct with a 100 mm outer diameter, long enough to reach outdoors.
Know your AirWave

Screen Knob - the round screen on the front. It is also the only control: turn it, short press it, or long press it.
Smoke Inlet - the lower port on the back. The silverskin collection module fits here, and the duct from your roaster connects to the module.
Air Outlet - the upper port on the back. The purified exhaust leaves here, through a duct you run outdoors.
Power On/Off Button - the switch on the back, beside the power cord.
Silverskin Collection Module - fits on the smoke inlet ahead of everything else and catches silverskin and particles larger than 300 microns before they reach the catalyst. The filter screen inside comes out for cleaning.
Catalyst - the NovaCat module inside the unit, where the smoke is converted. It cannot be washed.

How the smoke is removed. The heating element brings the catalyst up to temperature, 250 °C on Standard Filtration or 300 °C on Extreme Filtration. Hydrocarbons and carbon monoxide in the exhaust react with oxygen on the catalyst surface and leave as carbon dioxide and water vapor. Nothing is trapped, so there is no filter that fills up and stops working.
Fan speed is a trade-off. A higher fan speed pulls in more smoke, but the extra air lowers the catalyst temperature, and a cooler catalyst converts less of what passes through it. Turn the fan up only as far as you need to keep smoke from escaping at the roaster.
Check your roaster and your outlet
Batch size - up to 1 kg on the 220 V version and 800 g on the 120 V version. This is the batch you actually roast, not the roaster’s maximum capacity: a 1.2 kg roaster running 500 g batches is within range.
Exhaust temperature - the air reaching AirWave’s inlet has to stay below 120 °C. The supplied duct is rated to 150 °C, so measure the exhaust temperature at your roaster’s outlet before the first roast. If it runs hotter than 150 °C, use a higher-rated duct, or nest your roaster’s own duct inside the supplied one.
Airflow - AirWave moves up to 130 m³/h, or 80 m³/h once the ducts are connected. A roaster that pushes more exhaust than that may leak some smoke.
Power - the 220 V version needs an outlet rated 10 A or above, and the 120 V version 15 A or above. Don’t share the outlet with other appliances. If your supply voltage runs below AirWave’s rated voltage, it removes less smoke. If the plug doesn’t fit your socket, you need a transformer that matches AirWave’s rated voltage and current.
AirWave is not for use with gas hobs. With a gas roaster, keep the room well ventilated.
Connect the inlet duct
Use a tight connection at your roaster’s exhaust outlet and a loose connection at AirWave’s smoke inlet. If the duct and your roaster’s outlet are different sizes, fit an adapter, or sleeve your roaster’s own duct together with the supplied one.

Loosen the screw on a hose clamp and slide the smaller end of the silverskin collection module into it.

Insert the module and clamp into AirWave’s smoke inlet.

Tighten the screw so the module is held firmly on the smoke inlet.

Loosen the screw on a second hose clamp and slide one end of the air duct into it.

Push the duct and clamp onto the silverskin collection module and tighten the screw. Connect the other end to your roaster’s exhaust outlet.
Run the duct in smooth curves. Sharp bends reduce how much smoke reaches AirWave.
Connect the outlet duct

The exhaust from AirWave is mostly carbon dioxide and water vapor, and it is hot. Vent it outdoors through its own high-temperature-resistant duct with a 100 mm outer diameter, for example through an open window.
- Don’t connect AirWave’s outlet to your roaster’s exhaust duct.
- Never vent into a flue used by gas-burning or other fuel-burning appliances.
- Follow your local regulations for discharging air outdoors.
Power on and off
Leakage protection. The plug has a Reset button and a Test button. After any leakage trip, press Reset before AirWave will draw power again. To check the protection, press Test: Reset pops out, which means it works. Press Reset again to restore power.
Power on - press the power switch on the back. The screen shows the DiFluid logo, then the home screen.
Power off - after the roast, leave AirWave running until the catalyst temperature on the screen drops below 40 °C, then switch it off. Cutting the power while the catalyst is still hot shortens the heating element’s life.
The screen

| Action | What it does |
|---|---|
| Turn | Move through options, or change the fan speed while AirWave is running. |
| Short press | Confirm a choice. On the home screen, with Ready showing, a short press starts filtration. |
| Long press | Open the settings page. Long press again to go back to the home screen. |

1. Filtration level - Standard Filtration, Extreme Filtration or Fan Mode.
2. App connection - lights up when AirWave is connected to CoffeeOS.
3. Bluetooth broadcast - lights up when AirWave is discoverable over Bluetooth.
4. Ready - AirWave is on standby. Short press to start.
5. Inlet air temperature - the temperature of the exhaust coming in from the roaster.
6. Catalyst temperature - the current temperature of the catalyst. Watch this one before you power off.
Filtration levels
| Level | Catalyst | Max ideal fan speed | Use it for |
|---|---|---|---|
| Standard Filtration | 250 °C | 85% | Smoke in the early part of the roast, before second crack. |
| Extreme Filtration | 300 °C | 80% | The denser smoke before second crack. |
| Fan Mode | No heating | 95% by default, adjustable | Moving air early in the roast, when the smoke doesn’t need treating. |
You can switch levels at any time during a roast. On both filtration levels a slight smell in the exhaust is normal. The figures above were measured in laboratory testing on the 220 V version, and real results vary with the roaster.
Running Fan Mode for long periods without heating shortens the catalyst’s life. Newer firmware removes Fan Mode, so if your AirWave shows only Standard Filtration and Extreme Filtration, it is up to date.
Manual and Automatic Mode
Manual Mode - the default at power-up, on Extreme Filtration with the fan at 65%. Turn the knob to change the fan speed as the smoke changes through the roast.
Automatic Mode - works only with OmniFlux. AirWave adjusts its heating power to the smoke at each stage of the roast and sets its own fan speed. Pairing is covered in Part 2.
Settings

| Setting | What it does |
|---|---|
| 1. Gear | Standard Filtration, Extreme Filtration or Fan Mode. |
| 2. Mode | Manual Mode or Automatic Mode. |
| 3. Self-Cleaning | Runs the cleaning cycle. See Keep it clean. |
| 4. Wireless | On or off. Turn it on to connect AirWave to CoffeeOS or pair it with OmniFlux. |
| 5. Temperature Unit | °C or °F. |
| 6. Language | Simplified Chinese, English or Japanese. |
| 7. Device Information | Firmware version, serial number, device name, and the QR code for connecting AirWave to CoffeeOS. |
| 8. Factory Reset | Clears all history and restores the factory settings. |
Keep it clean
How often AirWave needs cleaning depends on how often you roast, which roaster it is connected to, and how much coffee goes through it. Always unplug AirWave before you clean it.
After every roast. Wipe the outside with a clean, soft cloth. Avoid strong chemical cleaners and abrasive tools.
Silverskin filter. Check how much silverskin the filter has collected after your first roast, and set your own cleaning schedule from that. To clean it, loosen the screw and remove the filter screen from the silverskin collection module. Wash it with water and a neutral detergent, using a brush if you need to. Let it dry completely before you put it back. A magnet holds it in place.

Smoke inlet. Dust builds up inside the inlet over time. Brush it loose, then pour it out or vacuum it out.

Ducts. Check both ducts regularly. Clean out a blockage, and replace a damaged duct.
Self-Cleaning. Run Self-Cleaning from the settings page after about every 50 kg of coffee roasted, and now and then when AirWave sits unused for a long time, to reactivate the catalyst. Otherwise, run it when the purification gets worse. Running it often shortens the heating element’s life.
Catalyst. The catalyst cannot be washed: water can strip the precious metal from it and reduce how well it works. It needs replacing when everything else works normally but the purification has clearly got worse, usually after one to two years depending on how much you roast. Send a photo of the catalyst to service@digitizefluid.com and a DiFluid technician will confirm it. AirWave Replacement Catalyst is sold separately.
Heating element. A spare heating wire comes in the box, and AirWave Heating Coil Replacement is sold separately in 110 V and 220 V versions.

Troubleshooting
| Problem | Check | What to do |
|---|---|---|
| An error code on the screen | See the error code table below. | Contact service@digitizefluid.com with a description, a video of the problem and the serial number, which is on the bottom of the unit. |
| AirWave won’t turn on | The plug is fully in and the outlet has power. The leakage protection hasn’t tripped. | Press Reset on the plug. If it still won’t turn on, contact support. |
| Weak suction or an unusual fan speed | Ducts blocked or damaged. Knob damaged. | Clean or replace the inlet duct. If the ducts are clear, contact support. |
| Smoke escaping, or poor smoke removal | Batch size within AirWave’s capacity. Silverskin collection module and ducts clear. | Roast a smaller batch, clean the module and ducts, then run Self-Cleaning. If nothing changes, the catalyst may need replacing. |
| A slight smell in the exhaust | Running on Standard Filtration or Extreme Filtration. | Normal. Nothing to fix. |
| Unusual noise while running | AirWave is sitting firmly and securely. | Secure it. If the noise continues, something may be inside the unit: contact support. |
Error codes
Each error shows a component code followed by an error code: an inlet air temperature above 120 °C, for example, shows as 1 and 080. Contact support for any error code. Two of them have a check you can make first.
| Code | Meaning | Possible cause |
|---|---|---|
| 0 · 001 | Mainboard above 60 °C | Cooling fan fault, or the cooling vent is blocked. Clear the vent, restart, and cool or ventilate the room. |
| 1 · 080 | Inlet air above 120 °C | Hot exhaust from the roaster. Turn the fan speed up, or loosen the inlet connection so room air is drawn in with the smoke. |
| 1 · 040 | Inlet air below −50 °C | Inlet temperature sensor fault. |
| 1 · 020, 010, 008, 004 | Inlet temperature sensor circuit, sensor or power supply fault | Inlet temperature sensor fault. |
| 2 · 080 | Outlet air above 420 °C | The fan motor stopped, so no air is moving, or the outlet temperature sensor is faulty. |
| 2 · 040, 020, 010, 008, 004 | Outlet temperature sensor reading too low, or a sensor or circuit fault | Outlet temperature sensor fault. |
| 3 · 001, 002 | Fan motor overcurrent | Fan motor fault. |
| 3 · 004, 008 | Overvoltage or undervoltage | Power supply problem. |
| 3 · 010, 200 | Locked rotor, or startup error | The fan motor is jammed. |
| 3 · 040 | Phase loss | Fan motor fault. |
| 3 · 080 | Fan motor overheating | The fan motor is overheating. |
| 4 · 001 | Heating fault | Heating element failure, or a damaged thyristor. |
Specifications
| Item | Value |
|---|---|
| Rated voltage | 220 V version: 220–240 V · 120 V version: 120 V |
| Rated frequency | 220 V version: 50/60 Hz · 120 V version: 60 Hz |
| Rated power | 220 V version: 2400 W · 120 V version: 1800 W |
| Roasting capacity | 220 V version: up to 1 kg · 120 V version: up to 800 g |
| Maximum airflow | 130 m³/h (80 m³/h with ducts connected) |
| Maximum inlet temperature | Below 120 °C |
| Supplied duct | Heat resistant up to 150 °C |
| Inlet and outlet duct diameter | 100 mm |
| Noise | Under 76 dB(A) |
| Weight (main unit) | About 6.9 kg |
| Dimensions (L × W × H) | 290 × 181 × 318 mm |
| Filtration levels | Standard Filtration, Extreme Filtration, Fan Mode |
| Operating modes | Manual Mode, Automatic Mode |
| Self-cleaning | Every 50 kg roasted, and periodically during long periods of disuse |
| Power supply | 220 V version: 10 A · 120 V version: 15 A |
Part 2: AirWave with OmniFlux and CoffeeOS
OmniFlux measures roast color in real time so you can Roast by Color. Pair it with AirWave and the fan speed follows the stages of your roast. Connect AirWave to CoffeeOS to keep its firmware up to date.
Pair AirWave with OmniFlux

Automatic Mode needs OmniFlux. Pair them once, with both powered on.
1. Choose Automatic Mode.
On AirWave, long press the screen to open the settings page. Turn the knob to Mode, short press, and select Automatic Mode.
2. Turn on Wireless.
Turn the knob to Wireless and short press to turn it on.
3. Find AirWave on OmniFlux.
On OmniFlux, from READY, swipe right and go to Settings > Device Settings > Connection Settings > AirWave Connection. Tap AirWave’s name when it appears, then swipe right to leave settings.
4. Go back to the home screen.
Long press AirWave’s screen to leave its settings page.
The first roast. With OmniFlux on the Roast Track page, adjust AirWave’s fan speed by hand as the smoke changes, or at yellowing and first crack. OmniFlux records every change.
Every roast after that. AirWave applies the recorded fan speeds automatically. You can still turn the knob during a roast, and the latest setting is used on the roasts that follow.
Connect AirWave to CoffeeOS
CoffeeOS is free to download from the App Store or Google Play, or from the QR code card in the box.
1. Turn on Wireless.
Power AirWave on, long press the screen, and turn Wireless on.
2. Prepare your phone.
Turn on Bluetooth and location, and allow every permission CoffeeOS asks for.
3. Connect.
Open the Tools tab in CoffeeOS and connect AirWave when it appears. You can also tap Scan in the Tools tab menu and scan the QR code under Device Information on AirWave.
The CoffeeOS connection icon on AirWave’s home screen lights up once it is connected.
Update the firmware
New firmware adds features and fixes problems, so install it when CoffeeOS offers it. AirWave has to be connected first, and should stay on until the update finishes.
1. Open the update.
Tap Upgrade when CoffeeOS shows that new firmware is available, or go to Me > Device Center, tap AirWave, then Firmware Upgrade.
2. Install it.
Read what is new in the Upgrade Log, choose an Upgrade Method, and tap Update.
Roast Control System
AirWave keeps the room clean. Add OmniFlux and Omix Plus for complete control over your roasting: Omix Plus measures moisture, water activity, density and screen size before the roast to help you set your charge temperature, OmniFlux lets you Roast by Color, and Omix Plus measures the final color and roast delta afterward. Roast Control System Ultimate brings all three together.