Manual (PDF)

DiFluid CoffMeter A1 User Manual

August 2026, V0.4

Read this manual carefully so you can use this product correctly and safely.

  • Thank you for purchasing CoffMeter A1 Coffee Roast Color Analyzer.
  • The information and specifications in this manual may change without notice as the product is improved.
  • Every effort was made to make this manual accurate at the time of writing. If you find an error, please let us know.

Video tutorial: watch how to set up and use CoffMeter A1

Using CoffMeter A1 with CoffeeOS: this manual covers operating the device. To sync your roast color readings to CoffeeOS and store them there, read the CoffMeter A1 Complete Guide.

Every manual, as a web page and a PDF: DiFluid Product Manuals

Caution

  • Do not open the casing unless you are a qualified service technician. Doing so voids the warranty and may damage the device or stop it working.
  • DiFluid is not responsible for any damage caused by using this product (including accessories) incorrectly.
  • DiFluid is not liable for direct, indirect or other damages arising from defects in this product, even if advised of the possibility of such damages, nor for any third-party claims.
  • If anything about the device seems wrong, contact the customer service of the store where you bought it.

About the Power Supply

This product uses a lithium-ion battery. For safety, follow these precautions when handling the battery:

!If you will not use the device for a long time, charge it fully before storing it, and charge it again from time to time. Storing it with a low battery can damage the hardware.

!Do not take apart or modify the battery. Damaging its safety mechanisms can cause overheating, smoke, bursting or fire.

!Do not charge the battery near flames or in high heat, such as direct sunlight. High temperatures can disable the safety circuits or trigger dangerous chemical reactions.

!If you notice a strange smell, heat, discoloration, deformation or anything else unusual while using, charging or storing the battery, stop using the product at once. Continuing can lead to overheating, smoke, bursting or fire.

Power Usage Precautions

  1. Charge the device when it will not turn on or the battery is low.
  2. The charging port is on the bottom of the device. Use the included USB cable or any standard USB cable.
  3. No USB power adapter is included. Use a 5V/0.5A adapter, sold separately.

Package Contents

CoffMeter A1 package contents: main unit, shallow groove for coffee grounds, deep groove for coffee beans, scraper, color calibration card, brush, USB-C charging cable, manual with warranty card, product QR code card and toolbox
  • Main unit
  • Shallow groove, for coffee grounds
  • Deep groove, for coffee beans
  • Scraper
  • Color calibration card
  • Brush
  • USB-C charging cable
  • Manual (including warranty card)
  • Product QR code card
  • Toolbox

Know Your Product

CoffMeter A1 main unit and the integrated grounds and beans dish, with numbered parts
  1. Main unit
  2. Touchscreen
  3. Charging port
  4. Button (power and test)
  5. Deep groove, for coffee beans
  6. Shallow groove, for coffee grounds

The main unit sits on the integrated grounds and beans dish, which has a deep groove on one side and a shallow groove on the other.

Main Screen

CoffMeter A1 main screen with numbered elements
NumberDescription
①Sample type currently selected. Before testing, tap to choose roasted beans or coffee grounds.
②History record number, generated automatically when a measurement finishes.
③App connection status. The phone icon is white when connected to the app and gray when not connected.
④Color value and roast level.
⑤Reference standard in use.
⑥Calibration button. Tap to start calibration.
⑦Test button. Tap to start measuring; all results appear together.
⑧Swipe right on the main screen to open the menu. (From any screen, swipe right to go back to the previous screen.)
⑨Swipe left on the main screen to see measurement history.

Settings Page

On the main screen, swipe from left to right to open the menu, then tap "Settings".

Opening the menu from the main screen, then tapping Settings
CoffMeter A1 Settings page with numbered items
NumberDescription
①Bluetooth: on by default. It must be on to connect to the app and record data.
②Reference Standard: SCA or COMMON.
③Language: Simplified Chinese, English, Japanese, Traditional Chinese, Korean or Spanish.
④Screen Brightness: adjust to suit your eyes.
⑤Auto Power-Off: Never, 3 minutes, 5 minutes or 10 minutes.
⑥Device Info: shows the device's unique serial number (SN) and current version number. Scan the QR code here to download the app and store your data.
⑦Factory Reset: press and hold, then swipe right to reset the device. All data and settings are cleared.

Calibration and Color Adjustment

Note

  • After calibration, if you want to test the calibration card to check its value, select "Grounds" as the sample type first. Otherwise the result will not match the card.

How to Calibrate

1. Before calibration: remove the protective cover from the calibration card. Do not scratch the color area of the card.
Removing the protective cover of the calibration card
Do not scratch the color area of the card
2. Power on: turn on CoffMeter A1 and snap the main unit onto the color calibration card.
Snapping the main unit onto the calibration card
3. Calibrate: tap "Calibration" to open the calibration page, enter the color value printed on the calibration card, and tap "Calibrate".
Tapping Calibration to open the calibration page
Entering the color value from the calibration card
4. Finish: when calibration is complete, put the cover back on the calibration card and store it safely.
Closing the protective cover of the calibration card

Changing the Calibration Card Value

1. Before calibration: check the value on the back of the calibration card. In this example the card reads 23 Agtron and you want to change it to 25.
Checking the value on the back of the calibration card
2. Power on: turn on CoffMeter A1 and snap the main unit onto the color calibration card.
Snapping the main unit onto the calibration card
3. Calibrate: open the calibration page and enter 25.
Tapping Calibration to open the calibration page
Entering the new value
4. Finish: tap "Calibrate". The calibration card value changes from 23 to 25. Put the cover back on the calibration card and store it safely.
Tapping Calibrate
Closing the protective cover of the calibration card

How to Measure

Before you test

  • Before testing, select the sample type at the top left of the main screen.
  • Supported sample types: roasted beans and coffee grounds.
  • Level the sample with the scraper so it is flush with the top of the integrated dish. Do not press it down.
  • Put coffee grounds in the shallow groove and coffee beans in the deep groove of the integrated dish.
1. Select the sample type: turn on CoffMeter A1 and tap the sample type at the top left to choose it.
Selecting the sample type at the top left of the screen
2. Add the sample: put roasted beans in the deep groove and ground coffee in the shallow groove.
Pouring beans into the dish
3. Level the sample: use the scraper to level the sample so it is flush with the top of the integrated dish. Do not press it down. If any area is not filled, add more beans.
Leveling the sample with the scraper
Adding beans where the groove is not fully filled
4. Test: snap the main unit onto the dish and tap "Test".
Snapping the main unit onto the dish
5. Clean the chamber: after measuring, clean the chamber with the supplied brush. Do not use steel wool or other hard materials on the inner container or the device body.
Cleaning the dish with the supplied brush
6. History: swipe left on the main screen to see all history records.
Swiping left to see history

Connecting to the App

Before you connect

  • On your phone, turn on Bluetooth and location services and allow every permission the app asks for.
  • If the device will not connect, check that Bluetooth is turned on in the device settings.

Download CoffeeOS

Scan a QR code below to download CoffeeOS from Google Play, the App Store or AppGallery.

QR codes to download CoffeeOS from Google Play, the App Store and AppGallery

First Connection

Method 1: turn on the device and open the app. The app shows a connection prompt automatically; tap "Connect".

Connecting from the automatic prompt in the app

Method 2: turn on the device, open the menu from the main screen, then tap Settings, then Device Info. Open the scanner in the app and scan the QR code on the device screen to connect.

Opening Device Info on the device to show its QR code

Reconnecting

Each time you turn the device on, open the app and it reconnects automatically.

The app reconnecting automatically and showing CoffMeter A1 Connected

Updating the Firmware

Check regularly for new firmware and update the device. New firmware improves the experience, adds convenient features and keeps performance stable.

Path: make sure the app is connected to the device, then tap Profile → Bluetooth → the device name, and update.

Updating firmware from the app

Uploading Data to the App

Make sure the app is connected to the device, then tap Profile → Data Sync → the device name, and tap "Sync".

Opening Data Sync from Profile in the app
Tapping Sync to upload data from the device

Roast Level Reference

Agtron valueCOMMONSCA
0 to 30EspressoVery Dark
above 30 to 40FrenchDark
above 40 to 50Full CityMedium Dark
above 50 to 60CityMedium
above 60 to 70DarkMedium Light
above 70 to 80MediumLight
above 80 to 90CinnamonVery Light
above 90 to 150LightExtremely Light

Specifications

ItemSpecification
NameCoffMeter A1
ModelCM-A101
MeasuresColor value, roast level
Sample typesRoasted beans, coffee grounds
Color valueRange 0 to 150 (Agtron)
Precision ±0.5
Resolution 0.1
Dimensions (L × W × H)74 × 74 × 70 mm
Weight (main unit)208 g
BatteryLithium battery
Battery capacity1500 mAh
Continuous run time8 hours
Charging time3 hours
Data storage500 records
Test time3 seconds
Operating temperature0 to 45 °C
Charging portUSB-C
Charging input5V ⎓ 0.5A

Cleaning and Maintenance

  1. If you will not use the device for a long time, charge it fully before storing it. A low battery can damage the hardware.
  2. After use, brush any residue out of the inner container and the main unit. Residue can affect measurement accuracy.
  3. Do not use steel wool or other hard materials to clean the inner container or the device body.
Charge fully before long storage
Brush residue out of the inner container and main unit
Do not use steel wool or hard materials on the device body

Warranty Policy

Faults that occur under normal use are repaired free of charge by DiFluid for one year from the date of purchase.

Not Covered by the Warranty

  1. Products bought outside DiFluid's official authorized sales channels, or without a warranty card and valid invoice.
  2. Products past the warranty period.
  3. Faults or damage caused by misuse, unauthorized modification, disassembly, repair or firmware flashing.
  4. Faults or damage caused by transport, handling or dropping after purchase.
  5. Accidental or deliberate damage, such as liquid getting inside, incorrect voltage input, excessive pressure, or scratches on the screen or casing.
  6. Faults or damage caused by force majeure, such as fire, earthquake or flood.

Compliance Information

Federal Communications Commission (FCC) Radiation Exposure Statement

The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications or changes to this equipment. Such modifications or changes could void the user's authority to operate the equipment.

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Caution: any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.

CE Compliance Notice

Hereby, Shenzhen Digitizing Fluid Technology Co., Ltd. declares that the radio equipment type CoffMeter A1 (CM-A101) is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at: https://www.difluidtech.com/support/document

Manufacturer: Shenzhen Digitizing Fluid Technology Co., Ltd., Room 1602, Jinhua Building, Longhua District, Shenzhen, China.

  • Do not use the product at too high or too low a temperature, and never expose it to strong sunlight or a very wet environment. The suitable temperature for the product and accessories is 0 to 45 °C.
  • Bluetooth: 2402 to 2480 MHz. EIRP (max): 8.22 dBm.
  • CAUTION: risk of explosion if the battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
  • If you use a third-party charger, the recommended output voltage and current of the adapter is 5 Vdc/0.5 A, and the adapter must be CE approved.
  • The device has been evaluated to meet general RF exposure requirements. The device can be used in portable exposure conditions without restriction.

Shenzhen Digitizing Fluid Technology Co., Ltd.
Room 1602, Jinhua Building, Longhua District, Shenzhen, China
(+86) 0755-23761557